background image

 

CUBE

 Manual 

                                                                        Page 55 – Revision 10‐8‐2018 

 

 

CUBE DRAINING INSTRUCTIONS 

 

 

Draining Notes 

There are 2 tanks that must be drained in the 

CUBE Water Treatment System. 

 

Prior to draining the Hot Tank, turn off Green Heater/Compressor Switch 
(

O=OFF

) located on back of the 

CUBE

 

Water Treatment System

  

 
Dispense 2 liters (0.5 gallons) of hot water from the machine.   
 
As Hot Water is dispensed from the faucet of the unit, colder water will be introduced into the Hot 
Tank.  Since the Green Power Switch is turned off, the Heater will not energize and heat the incoming 
tap water.   
 
Following this precaution prevents exposing personnel and equipment (drains, catch basin, etc.) to 
scalding hot water. 

 

 

WARNING!  

VERY HOT WATER.  Unit produces Very Hot Water up to 203

o

F.  

Water above 125

o

can cause severe burns or scalding.  Hot water should be dispensed carefully into insulated container 
to avoid injury. 

 

 

Disable Cold and Hot Tanks 

 

1.

 

Turn off the Green Power Heater and Compressor Switch to disable the heater 
and compressor.

 

O=OFF

 

 

 

2.

 

Dispense 2 liters of water through the Hot Tank to cool the water temperature in the Hot Tank and 
avoid burns.       

 

 

WARNING!  

VERY HOT WATER.  Unit produces Very Hot Water up to 203

o

F.  

Water above 125

o

can cause severe burns or scalding.  Hot water should be dispensed carefully into insulated container 
to avoid injury. 

 

Turn off Water Supply and Bleed Water Pressure 

 

3.

 

Isolate the unit from feed water by turning off the supply.  

 

4.

 

Dispense cold still water to relieve any pressure built up in the system. 

 

5.

 

Remove the water supply line from the unit. 

 

6.

 

Install dust cap or plug into water supply line bulkhead fitting. 

 

7.

 

Remove the Hot and Cold drain line cap and always allow tanks to drain and reinstall all drain caps. 

 

Summary of Contents for CUBE

Page 1: ...ypochlorite or Citric Acid Based Cleaner Plastic Tubing at least 4 feet in length and assorted quick connect fittings TDS Meter and Test Strips for measuring chlorine Optional 1 8 NPT Female Thread to...

Page 2: ...ts of each chemical product Take all necessary precautions to prevent sanitizer from contacting eyes clothing and any other surfaces in could damage carpets 3 Remove the two screws at the rear of the...

Page 3: ...cure with two screws holding Top Cover in place 14 Connect 40 60 psi regulated potable water supply to the water inlet bulkhead fitting located on the back of the Cube Water Treatment System Turn on w...

Page 4: ...h 10 liters of cold water and 4 liters of ambient water through the machine to dilute and remove the sanitizer from the cold circuit You can use chlorine test strips to evaluate the water 19 Once the...

Page 5: ...green heater compression switch is in the O OFF CAUTION NEVER TURN ON HEATER BEFORE FILLING HOT TANK Green Heater and Compressor Power Switch must be in the O OFF position while the hot tank is empty...

Page 6: ...an cause severe burns or scalding Hot water should be dispensed carefully into insulated container to avoid injury Disable Cold and Hot Tanks 1 Turn off the Green Power Heater and Compressor Switch to...

Page 7: ...e above 97 F 3 6C or below 50 F 10 C Install indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrig...

Page 8: ...le tubing to the Reducer and the Water Supply Waterlogic requires the use of a water pressure regulator Water feed pressure must be between 40 60 psi 2 Turn on the water supply and check all of the co...

Page 9: ...tes Once a continuous flow is obtained flush 5 liters of water by continuing to hold the hot button Hot Tank is now full 10 Prime the Cold Circuit Holding a container under the dispensing faucet Selec...

Page 10: ...kin and eyes against ultraviolet rays Never look directly at an operating UV light Always disconnect before removal 16 Move the Waterlogic CUBE Water Treatment System into its final operating position...

Reviews: