CUBE

 Manual 

                                                                        Page 58 – Revision 10‐8‐2018 

 

 

 
6.

 

Place a container in the dispense area for flushing process.  The filter will now 
need to be flushed.   

 
 
 
 
 
 

7.

 

 Turn off both the Red Power and the Green Heater / Compressor Switch’s.  

O=OFF

  

 
 

NOTE:

  Switches have internal LED that illuminates when placed in 

I=ON 

position. 

 

 

       CAUTION!  

NEVER TURN ON HEATER BEFORE FILLING HOT TANK. 

Green Compressor/Heater Switch must be in the O=OFF position while the Hot Tank is empty.  
Damage could occur within one minute and the overload (high limit) will require manual reset if 
heater is turned on with an empty Hot Tank.  

 

8.

 

Select the Ambient Water Icon followed by the main dispensing button, dispense 10 liters of water.  
This will remove excess carbon fines and sufficiently generate the filter. 
 

9.

 

Prime the Hot Tank.  Holding a container under the dispensing faucet, press the hot button until it 
lights up.   While the hot water icon is lit, select and hold the central dispense button until a 
continuous flow of water is obtained (this could take 2 to 4 minutes).  Once a continuous flow is 
obtained, flush 5 liters of water by continuing to hold the hot button.  Hot Tank is now full.  

 
 

10.

 

Prime the Cold Circuit.  Holding a container under the dispensing faucet, Select and hold the cold‐
water icon until it lights up. While the cold‐water icon is lit, select the central dispense button to 
start filling the cold tank with water. After one minute, the machine will automatically un‐select the 
central dispense button. Repeat selection of the central dispense button until the cold tank has filled 
and water is coming out of the faucet (this could take 2 to 4 minutes), press and hold the main 
dispensing button until a continuous flow of water is obtained.  Once a continuous flow is obtained, 
release the dispensing button.  Cold tanks are now full.   
 

11.

 

Prime the Ambient Circuit.  Holding a container under the dispensing faucet, Select and hold the 
Ambient water icon until it lights up. While the Ambient water icon is lit, select the central dispense 
button to start filling the Ambient line with water (this could take 10 – 20 seconds).  Continue to 
dispense 15‐20 fluid ounces more of water through the ambient option.     
 
 

12.

 

Turn on the Green Heater/ Compressor switch at the rear of the machine. 

 
 
 
 

Summary of Contents for CUBE

Page 1: ...ypochlorite or Citric Acid Based Cleaner Plastic Tubing at least 4 feet in length and assorted quick connect fittings TDS Meter and Test Strips for measuring chlorine Optional 1 8 NPT Female Thread to...

Page 2: ...ts of each chemical product Take all necessary precautions to prevent sanitizer from contacting eyes clothing and any other surfaces in could damage carpets 3 Remove the two screws at the rear of the...

Page 3: ...cure with two screws holding Top Cover in place 14 Connect 40 60 psi regulated potable water supply to the water inlet bulkhead fitting located on the back of the Cube Water Treatment System Turn on w...

Page 4: ...h 10 liters of cold water and 4 liters of ambient water through the machine to dilute and remove the sanitizer from the cold circuit You can use chlorine test strips to evaluate the water 19 Once the...

Page 5: ...green heater compression switch is in the O OFF CAUTION NEVER TURN ON HEATER BEFORE FILLING HOT TANK Green Heater and Compressor Power Switch must be in the O OFF position while the hot tank is empty...

Page 6: ...an cause severe burns or scalding Hot water should be dispensed carefully into insulated container to avoid injury Disable Cold and Hot Tanks 1 Turn off the Green Power Heater and Compressor Switch to...

Page 7: ...e above 97 F 3 6C or below 50 F 10 C Install indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrig...

Page 8: ...le tubing to the Reducer and the Water Supply Waterlogic requires the use of a water pressure regulator Water feed pressure must be between 40 60 psi 2 Turn on the water supply and check all of the co...

Page 9: ...tes Once a continuous flow is obtained flush 5 liters of water by continuing to hold the hot button Hot Tank is now full 10 Prime the Cold Circuit Holding a container under the dispensing faucet Selec...

Page 10: ...kin and eyes against ultraviolet rays Never look directly at an operating UV light Always disconnect before removal 16 Move the Waterlogic CUBE Water Treatment System into its final operating position...

Reviews: