Sanitizing 
 

Sanitize using a Household Bleach (5.25% Sodium Hypochlorite solution) or other approved cleaner 
throughout the cold and sparkling water circuits.  Follow all instructions on the sanitizer and flush 
with fresh water through the faucet until odor and taste is acceptable. 

 

       WARNING!  

USE PROPER PERSONAL PROTECTIVE EQUIPMENT

 

Always ensure proper ventilation and use proper personal protective equipment such as gloves 
and eye protection when using chemicals.  Refer to Material Safety Data Sheet for specific 
requirements of each chemical product. Take all necessary precautions to prevent sanitizer from 
contacting eyes, clothing, and any other surfaces in could damage (carpets).   

 

3.

 

Remove the two screws at the rear of the machine that hold the Top Cover in place.

 

 

 
 

 

4.

 

Remove the Top Cover by placing your hands on the Top in the picture and push it 
backwards and then lift it up to remove. 

 
 
 
 

DANGER!  

HIGH VOLTAGE ELECTRICAL HAZARD.  

Unplug before inspection and 

service. 

 

5.

 

Visually inspect all electrical and water connections for signs of wear or damage.  The 

CUBE

 should 

not be energized during inspection at this point. 

 

 

6.

 

Insert finger into the round hole of the filter head.  Pull to vertical 
position. 

 
 
 
 
 

7.

 

Pull the lever straight up to remove the filter assembly.  Slight force may be required. 

 
 
 
 
 
 
 
 

Summary of Contents for CUBE

Page 1: ...ypochlorite or Citric Acid Based Cleaner Plastic Tubing at least 4 feet in length and assorted quick connect fittings TDS Meter and Test Strips for measuring chlorine Optional 1 8 NPT Female Thread to...

Page 2: ...ts of each chemical product Take all necessary precautions to prevent sanitizer from contacting eyes clothing and any other surfaces in could damage carpets 3 Remove the two screws at the rear of the...

Page 3: ...cure with two screws holding Top Cover in place 14 Connect 40 60 psi regulated potable water supply to the water inlet bulkhead fitting located on the back of the Cube Water Treatment System Turn on w...

Page 4: ...h 10 liters of cold water and 4 liters of ambient water through the machine to dilute and remove the sanitizer from the cold circuit You can use chlorine test strips to evaluate the water 19 Once the...

Page 5: ...green heater compression switch is in the O OFF CAUTION NEVER TURN ON HEATER BEFORE FILLING HOT TANK Green Heater and Compressor Power Switch must be in the O OFF position while the hot tank is empty...

Page 6: ...an cause severe burns or scalding Hot water should be dispensed carefully into insulated container to avoid injury Disable Cold and Hot Tanks 1 Turn off the Green Power Heater and Compressor Switch to...

Page 7: ...e above 97 F 3 6C or below 50 F 10 C Install indoors and keep unit away from excessive humidity Never expose to freezing temperatures Ensure there is adequate clearance around the unit to allow refrig...

Page 8: ...le tubing to the Reducer and the Water Supply Waterlogic requires the use of a water pressure regulator Water feed pressure must be between 40 60 psi 2 Turn on the water supply and check all of the co...

Page 9: ...tes Once a continuous flow is obtained flush 5 liters of water by continuing to hold the hot button Hot Tank is now full 10 Prime the Cold Circuit Holding a container under the dispensing faucet Selec...

Page 10: ...kin and eyes against ultraviolet rays Never look directly at an operating UV light Always disconnect before removal 16 Move the Waterlogic CUBE Water Treatment System into its final operating position...

Reviews: