background image

 

 
2.  Position the drain saddle assembly in the selected location and mark the spot through the 

threaded outlet with a pencil or marker 

 

3. 

Drill a ¼” hole at the marked spot.  Strip the backing paper from the adhesive side of the 
saddle  gasket  and  position  on  the  inside  of  the  drain  saddle,  aligning  the  hole  with  the 
threaded outlet.  Attach the drain saddle to the drainpipe, aligning the push-on port with the 
drilled hole.  Tighten the clamp snugly. DO NOT OVER TIGHTEN. 

 

4.  The black drain tube may be inserted directly into the push-on drain port, using instructions 

in Step 8. below.  Do not attach poly tube at this time. 

 

Step 6. Install the Tank Valve, Preparing the Storage Tank 

1.  Wrap the threaded storage tank nipple with two wraps of Teflon tape.  Thread on tank shut- 

off  valve  until  snug.    Using  the  wrench,  turn  an  additional  ¼  turn.    DO  NOT  OVER 
TIGHTEN.   Open tank valve to the fully open position. 

 

Step 7. Mounting the RO Unit  

1.  While  holding  the  RO  unit  in  its  mounting  position,  mark  the  holes  for  the  wall  screws.  

Using a 1/8” bit, drill the pilot holes for the screws.  Screw in the mounting screws leaving 
¼” protruding.  Hang the RO mounting bracket on the screws and tighten. 

 
2.   If  the  unit  is  to  be  mounted  on  wallboard,  use  plastic  screw  anchors,  available  at  any 

builder’s supply and follow the manufacturer’s directions. 

 

3. 

DO  NOT  INSTALL  FILTER  CARTRIDGES  OR  THE  RO  MEMBRANE  AT  THIS  TIME.  

Spin the filter housing sumps on to the RO unit and hand-tighten.  On Vectapure II units the 
clear  housing  always  is  installed  on  the  right-hand  side.    WR-2  Series  use  only  white 
opaque housings.  Use the wrench provided to turn an additional ¼ turn. 

 
Step 8. Connect the System Tubing  
 

Making and securing a push on 

connection  is  simple.    First,  the 

tubing should be cut square and 

any  burrs  or  rough  edges 

removed.  Insert the tube firmly 

and  push  until  the  tube  end 

contacts  the  stop.    Gently  tug 

the  tube  backwards  to  assure  a 

secure 

connection. 

 

To 

disconnect,  pull  the  tube  while 

pushing  in  the  collet  ring.    The 

joint may be used over and over 

again, if necessary. 
 

 

1.  Connect  the  cold  water  supply  valve  to  the  first  filter  housing  water  inlet  push-on  fitting 

(marked “water inlet”), after cutting the ¼” clear tube to the length required.  

 

 

 

 

2. 

Connect  the  black  ¼”  tube  from  the  end  of  the  flow  restrictor  (marked  “to  drain”)  to  the 
Drain Saddle push-on connection (your black drain tube may be pre-attached to your RO).  
Please note that the drain line flow restrictor has been installed INSIDE the black drain tube 

Summary of Contents for Vectapure II RO-4042H

Page 1: ...IS TO BE LEFT WITH THE OWNER OF THE EQUIPMENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN...

Page 2: ...are allowed to pass through and collect in the tube while all other mineral and contaminant molecules are rejected and washed from the surface of the membrane to the drain Q What processes does the Ve...

Page 3: ...ATER SOURCE THIS IS NECESSARY TO PERIODICALLY PURGE AND FLUSH THE SYSTEM WITH WATER THAT HAS A CHLORINE RESIDUAL TO SANITIZE PARTS OF THE SYSTEM THAT NORMALLY ARE EXPOSED TO WATER THAT HAS BEEN DECHLO...

Page 4: ...ut caused by higher TDS System pressure may not however exceed 90PSI Q How much water does the Vectapure II system produce All Vectapure systems use membranes nominally rated for 75GPD Actual output w...

Page 5: ...ng screws 5 m 15 white Poly tubing for water connections 3m 10 black Poly tubing for drain connections One plastic tank shut off valve One filter housing wrench One Owner s package including owner s m...

Page 6: ...scent wrench a sharp knife X Acto type knife is best Teflon plumbing tape adjustable pliers a rat tail file a center punch a medium flat head screwdriver a small household funnel Always wear eye prote...

Page 7: ...n Use a 5 8 masonry bit to drill the concrete sink 4 If you have a porcelain enamel or ceramic sink it is strongly recommended that a professional install the faucet to avoid chipping and damaging the...

Page 8: ...racket on the screws and tighten 2 If the unit is to be mounted on wallboard use plastic screw anchors available at any builder s supply and follow the manufacturer s directions 3 DO NOT INSTALL FILTE...

Page 9: ...age tank fill with water Open the faucet at the sink and let the water run free for 10 minutes Turn the saddle valve OFF Leave the faucet open and drain all the water from the tank until water flow st...

Page 10: ...again and fix if necessary DO NOT USE ANY WATER FROM THE SYSTEM UNTIL THE NEXT STEP IS COMPLETE 4 Open the storage tank valve and close the faucet The system is now operating and filling the storage t...

Page 11: ...o load the new cartridges 4 To load the cartridges repeat Step 9 3 or 4 from the installation instructions above Turn the raw water supply valve ON Allow the storage tank to fill and then drain it com...

Page 12: ...iod Read the document completely for warranty claim instructions BE SURE TO RETURN THE VECTAPURE WARRANTY CARD LOCATED IN YOUR LITERATURE KIT THIS IS NECESSARY TO VALIDATE YOUR PRODUCT WARRANTY Sectio...

Page 13: ...SWI H RO4152H only 3 Male elbow push on 1 4 A4ME4 20 4 way shutoff valve ROS002 Tee push on 1 4 A4TU4 21 RO storage tank ROT 4 5 Sani purge valve A6HVUC6 22 Tank valve push on 1 4 EA3931 6 Mounting br...

Page 14: ...14 VECTAPURE II RESIDENTIAL REVERSE OSMOSIS SYSTEM FLOW LAYOUT RO4042H RO4052H Not included on RO4042H...

Page 15: ...15 VECTAPURE II RESIDENTIAL REVERSE OSMOSIS SYSTEM FLOW LAYOUT RO415H...

Page 16: ...OGIES WEBSITE FOR INFORMATION CONSUMER ONLINE REPLACEMENT PARTS AND PRODUCT UPDATES AT www waterite com Waterite Technologies Inc 3 75 Meridian Drive Winnipeg Manitoba Canada R2R 2V9 204 786 1604 204...

Reviews: