background image

 

Q: When should the membrane be changed? 

If  you  notice  gradually  decreasing  production  from  your  system,  differing  taste  to  your  drinking 
water  or  a  white  scale  forming  on  pans  or  dishes,  it  probably  means  that  your  membrane  is 
deteriorating  and  is  losing  its  effectiveness.      You  may  purchase  a  pocket  TDS  meter  from  your 
dealer - this is the best way to assure you system is operating efficiently. 

 

Section 2. Unpacking and Installation 

 

Your system includes: 

Carton Contents 

  The main RO/filter unit assembly with 4 or 5 stages.  The RO-4152H model will include a 

booster pump mounted on the main bracket; 

  One membrane (in a sealed plastic bag), one combo carbon/sediment filter cartridge, one 

block carbon filter cartridge and one polypropylene sediment cartridge (no white sediment 
cartridge with RO-4042H); 

  One drain fitting and clamp with push-on tube fitting; 

  One cold water supply adapter; 

  One low-lead (stainless is optional) long reach Quick Faucet and mounting hardware; 

 

Two #10 X1” Wall mounting screws; 

 

5 m (15’) - white ¼” Poly tubing for water connections; 

 

3m (10’) – black ¼” Poly tubing for drain connections; 

  One plastic tank shut-off valve; 

  One filter housing wrench; 

 

One Owner’s  package including  owner’s  manual,  warranty  certificate,  Extended Warranty 
Plan enrolment form, Waterite Parts Program enrolment form; 

  One 12 litre (4 gallon) RO holding tank. 

 

Step 1.  Selecting the System Location 

1.  This reverse osmosis system is designed for installation under a sink.  It can however, be 

mounted  anywhere  within  20  feet  of  the  faucet,  such  as  the  basement  or  adjoining  utility 
room.    Keep  in  mind  that  filter  housings  will  need  periodic  replacement  and  that  easy 
access must be maintained.  Do not install in a location with high humidity, direct sun or a 
direct  source  of  heat.    Both  the  RO  system  and  the  tank  may  be  installed  horizontally  or 
vertically.    If  you  are  installing  a  RO  4152H  model,  you  will  need  a  standard  110V  plug 
nearby. 

                  Figure 1. 

Booster pump (RO-4152H)   

 

 

 

 

 

 

 

 

 

 

 

 

Holding Tank and valve 
 
    Mounting bracket         

 

 

 

 

 

 

 

Membrane housing 

 

Faucet and mounting hdwe 

 

 

 

 

        

 

 

Sani-purge valve 

    
  

Carbon post-filter 

 

 

 

 

 

 

 

 

 

 
            Sediment pre-filter 

 

 

 

 

 

 

 

Drain clamp and fitting 

 

  Membrane element   

 

 

 

 

 

         

 

 

 

 

 

 

 

 

 

 

 

 

Water supply adapter 

 

Combo pre-filter 

 

 

 

 

 

 

 

 

5m ¼” poly tube (clear) 

Summary of Contents for Vectapure II RO-4042H

Page 1: ...IS TO BE LEFT WITH THE OWNER OF THE EQUIPMENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN...

Page 2: ...are allowed to pass through and collect in the tube while all other mineral and contaminant molecules are rejected and washed from the surface of the membrane to the drain Q What processes does the Ve...

Page 3: ...ATER SOURCE THIS IS NECESSARY TO PERIODICALLY PURGE AND FLUSH THE SYSTEM WITH WATER THAT HAS A CHLORINE RESIDUAL TO SANITIZE PARTS OF THE SYSTEM THAT NORMALLY ARE EXPOSED TO WATER THAT HAS BEEN DECHLO...

Page 4: ...ut caused by higher TDS System pressure may not however exceed 90PSI Q How much water does the Vectapure II system produce All Vectapure systems use membranes nominally rated for 75GPD Actual output w...

Page 5: ...ng screws 5 m 15 white Poly tubing for water connections 3m 10 black Poly tubing for drain connections One plastic tank shut off valve One filter housing wrench One Owner s package including owner s m...

Page 6: ...scent wrench a sharp knife X Acto type knife is best Teflon plumbing tape adjustable pliers a rat tail file a center punch a medium flat head screwdriver a small household funnel Always wear eye prote...

Page 7: ...n Use a 5 8 masonry bit to drill the concrete sink 4 If you have a porcelain enamel or ceramic sink it is strongly recommended that a professional install the faucet to avoid chipping and damaging the...

Page 8: ...racket on the screws and tighten 2 If the unit is to be mounted on wallboard use plastic screw anchors available at any builder s supply and follow the manufacturer s directions 3 DO NOT INSTALL FILTE...

Page 9: ...age tank fill with water Open the faucet at the sink and let the water run free for 10 minutes Turn the saddle valve OFF Leave the faucet open and drain all the water from the tank until water flow st...

Page 10: ...again and fix if necessary DO NOT USE ANY WATER FROM THE SYSTEM UNTIL THE NEXT STEP IS COMPLETE 4 Open the storage tank valve and close the faucet The system is now operating and filling the storage t...

Page 11: ...o load the new cartridges 4 To load the cartridges repeat Step 9 3 or 4 from the installation instructions above Turn the raw water supply valve ON Allow the storage tank to fill and then drain it com...

Page 12: ...iod Read the document completely for warranty claim instructions BE SURE TO RETURN THE VECTAPURE WARRANTY CARD LOCATED IN YOUR LITERATURE KIT THIS IS NECESSARY TO VALIDATE YOUR PRODUCT WARRANTY Sectio...

Page 13: ...SWI H RO4152H only 3 Male elbow push on 1 4 A4ME4 20 4 way shutoff valve ROS002 Tee push on 1 4 A4TU4 21 RO storage tank ROT 4 5 Sani purge valve A6HVUC6 22 Tank valve push on 1 4 EA3931 6 Mounting br...

Page 14: ...14 VECTAPURE II RESIDENTIAL REVERSE OSMOSIS SYSTEM FLOW LAYOUT RO4042H RO4052H Not included on RO4042H...

Page 15: ...15 VECTAPURE II RESIDENTIAL REVERSE OSMOSIS SYSTEM FLOW LAYOUT RO415H...

Page 16: ...OGIES WEBSITE FOR INFORMATION CONSUMER ONLINE REPLACEMENT PARTS AND PRODUCT UPDATES AT www waterite com Waterite Technologies Inc 3 75 Meridian Drive Winnipeg Manitoba Canada R2R 2V9 204 786 1604 204...