background image

 

at the waste elbow, on the membrane housing.  Place the storage tank in the location you 
have chosen for it.  Using the clear 3/8” tube connect the system fitting marked “to tank” to 
the tank valve.  Connect the 3/8’” tube attached to the faucet to the system fitting marked 
“to faucet”.  If the tubing is not pre-attached to the faucet, cut the 3/8” clear tubing to the 
desired length and attach the tube to the fitting at the base of the faucet shank to the fitting 
marked “ to faucet” on the RO unit. 

 

3.  You  may  find  that  your  unit  does  not  have  labels  attached  to  indicate  the  water  line  and 

drain  line  connections.    The  photos  below  are  labelled  with  the  correct  locations  for  the 
water and drain connections.   
 

   

To Storage Tank 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

        Raw Water Inlet   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

     

 
To Drain  

 

 

 

 

 

  

 

            To Faucet 

 

            

Top View 

 

 

 

 

 

Back View 

 

Step 9.  Filling and Sani-Flushing the System 

1.  Turn on the feed water adapter valve and check all connections for leaks.  Do not proceed 

further until any leaks are fixed. 

 
2.  Let the RO system and the storage tank fill with water.  Open the faucet at the sink and let 

the water run free for 10 minutes.  Turn the saddle valve OFF.  Leave the faucet open and 
drain all the water from the tank until water flow stops. 

 

!

 

THOROUGHLY  WASH  HANDS  BEFORE  LOADING  CARTRIDGES  AND  MEMBRANE 
ELEMENTS. 

 

3.  a)  Vectapure  II  Models:  Remove  the  clear  prefilter  housing  by  turning  counter  clockwise 

with  the  housing  wrench  supplied.    Remove  all  protective  wrapping  from  the  filter 
cartridges.  Insert the 5-micron combo carbon/sediment filter cartridge in the clear housing 
and reassemble housing.  The housings are seated with o-rings 

– DO 

NOT OVER TIGHTEN 

– 1/4 turn after hand tight is usually sufficient.  

Repeat  with  the  white  1-micron  sediment  cartridge  in  the  middle 
housing  (RO-4052H  and  RO-4152H  only).      Install  carbon  block 
cartridge in the remaining white filter housing and reassemble. 

 

4.  b)  WR2  Models:    Remove  the  left  housing  by  turning  clockwise  with 

the  housing  wrench  supplied.    Remove  all  protective  wrapping  from 
the  filter  cartridges.    Insert  the  5-micron  white  sediment  cartridge 
(carbon  cartridge  in  two-housing  WR2  units)  in  the  housing  and 
reassemble.  The housings are seated with o-rings 

– DO NOT OVER 

Summary of Contents for Vectapure II RO-4042H

Page 1: ...IS TO BE LEFT WITH THE OWNER OF THE EQUIPMENT FOR REFERENCE PURPOSES AND TECHNICAL GUIDANCE IT IS STRONGLY RECOMMENDED THAT QUALIFIED DEALER SERVICE PERSONNEL BE CONTACTED IN THE EVENT OF AN UNKNOWN...

Page 2: ...are allowed to pass through and collect in the tube while all other mineral and contaminant molecules are rejected and washed from the surface of the membrane to the drain Q What processes does the Ve...

Page 3: ...ATER SOURCE THIS IS NECESSARY TO PERIODICALLY PURGE AND FLUSH THE SYSTEM WITH WATER THAT HAS A CHLORINE RESIDUAL TO SANITIZE PARTS OF THE SYSTEM THAT NORMALLY ARE EXPOSED TO WATER THAT HAS BEEN DECHLO...

Page 4: ...ut caused by higher TDS System pressure may not however exceed 90PSI Q How much water does the Vectapure II system produce All Vectapure systems use membranes nominally rated for 75GPD Actual output w...

Page 5: ...ng screws 5 m 15 white Poly tubing for water connections 3m 10 black Poly tubing for drain connections One plastic tank shut off valve One filter housing wrench One Owner s package including owner s m...

Page 6: ...scent wrench a sharp knife X Acto type knife is best Teflon plumbing tape adjustable pliers a rat tail file a center punch a medium flat head screwdriver a small household funnel Always wear eye prote...

Page 7: ...n Use a 5 8 masonry bit to drill the concrete sink 4 If you have a porcelain enamel or ceramic sink it is strongly recommended that a professional install the faucet to avoid chipping and damaging the...

Page 8: ...racket on the screws and tighten 2 If the unit is to be mounted on wallboard use plastic screw anchors available at any builder s supply and follow the manufacturer s directions 3 DO NOT INSTALL FILTE...

Page 9: ...age tank fill with water Open the faucet at the sink and let the water run free for 10 minutes Turn the saddle valve OFF Leave the faucet open and drain all the water from the tank until water flow st...

Page 10: ...again and fix if necessary DO NOT USE ANY WATER FROM THE SYSTEM UNTIL THE NEXT STEP IS COMPLETE 4 Open the storage tank valve and close the faucet The system is now operating and filling the storage t...

Page 11: ...o load the new cartridges 4 To load the cartridges repeat Step 9 3 or 4 from the installation instructions above Turn the raw water supply valve ON Allow the storage tank to fill and then drain it com...

Page 12: ...iod Read the document completely for warranty claim instructions BE SURE TO RETURN THE VECTAPURE WARRANTY CARD LOCATED IN YOUR LITERATURE KIT THIS IS NECESSARY TO VALIDATE YOUR PRODUCT WARRANTY Sectio...

Page 13: ...SWI H RO4152H only 3 Male elbow push on 1 4 A4ME4 20 4 way shutoff valve ROS002 Tee push on 1 4 A4TU4 21 RO storage tank ROT 4 5 Sani purge valve A6HVUC6 22 Tank valve push on 1 4 EA3931 6 Mounting br...

Page 14: ...14 VECTAPURE II RESIDENTIAL REVERSE OSMOSIS SYSTEM FLOW LAYOUT RO4042H RO4052H Not included on RO4042H...

Page 15: ...15 VECTAPURE II RESIDENTIAL REVERSE OSMOSIS SYSTEM FLOW LAYOUT RO415H...

Page 16: ...OGIES WEBSITE FOR INFORMATION CONSUMER ONLINE REPLACEMENT PARTS AND PRODUCT UPDATES AT www waterite com Waterite Technologies Inc 3 75 Meridian Drive Winnipeg Manitoba Canada R2R 2V9 204 786 1604 204...