IMPORTANT

Safety Instructions • Be sure to read.

This  tank  is  designed  for  use  with  potable 
water,  limited  to  a  maximum  pressure  of  100 

psi and a maximum working temperature of 130°F. Please note: a 
hot water heater or a boiler in a hydronic heating system will heat 
water hotter than 130°F routinely. Use a thermal expansion tank 
for  hot  water  overflow  from  a  hot  water  heater,  or  use  an 
expansion  tank  for  hot  water  overflow  in  a  hydronic  heating 
system.  See  the  owner’s  manual  for  your  pump  for  output 
information.

EXPLOSION  OR  RUPTURE  HAZARD

  A  relief 

valve must be installed to prevent pressure in 

excess of local code requirement or maximum working pressure 
designated  in  the  Product  Manual,  whichever  is  less.    Do  not 
expose  Product  to  freezing  temperatures  or  temperatures  in 
excess of 200° F.  Do not adjust the pre-charge or re-pressure this 
Product except for any adjustments required at the time of initial 
installation,  especially  if  Product  corroded,  damaged  or  with 
diminished integrity.  Adjustments to pre-charge must be done at 
ambient temperature only.  Failure to properly size the Product or 
follow  these  instructions  may  result  in  excessive  strain  on  the 
system  lead  to  Product  failure,  serious  or  fatal  personal  injury, 
leakage and/or property damage.

This  Product,  like  most  Products  under 
pressure, may over time corrode. Weaken and 

burst  or  explode,  causing  serious  or  fatal  injury,  leaking  or 
flooding  and/or  property  damage.    To  minimize  risk,  a  licensed 
professional must install and periodically inspect and service the 
Product.    A  drip  pan  connected  to  an  adequate  drain  must  be 
installed if leaking or flooding could cause property damage.  Do 
not  locate  in  an  area  where  leakage  of  the  tank  or  connections 
could  cause  property  damage  to  the  area  adjacent  to  the 
appliance or to lower floors of the structure.

Chlorine  &  Aggressive  Water

:  The  water 

quality  can  significantly  influence  the  life  of 

this Product.  You should test for corrosive elements, acidity, total 
solids  and  other  relevant  contaminants,  including  chlorine  and 
treat your water appropriately to insure satisfactory performance 
and prevent premature failure. 

Note:

  Inspect for shipping damage and notify freight carrier or 

store  where  purchased  immediately  if  damage  is  present.    To 
avoid risk of personal injury and property damage, if the product 
appears to be malfunctioning or shows signs of corrosion, call a 
qualified professional immediately.  Current copies of the Product 
manual can be viewed at www.waterworkerdiy.com.  Use proper 
safety equipment when installing.

As in all plumbing products and water storage 

vessels,  bacteria  can  grow  in  this  Product, 

especially during times of non-use.  Consult your local plumbing 
professional regarding any steps you may wish to take to safely 
disinfect your home’s plumbing system. 

DANGER!  EXPLOSION  HAZARD,  WHEN  THE 
WELL  TANK  HAS  BEEN  IN  SERVICE  AND  A 

CHANGE TO A HIGHER PRE-CHARGE PRESSURE IS NECESSARY 

DUE  TO  A  REQUIRED  CHANGE  IN  THE  PRESSURE  SWITCH 
SETTING,  FAILURE  TO  FOLLOW  INSTRUCTION  MANUAL  CAN 
CAUSE  A  RUPTURE  OR  EXPLOSION,  POSSIBLY  CAUSING 
SERIOUS OR FATAL INJURY, AND/OR PROPERTY DAMAGE.

DO NOT ADJUST THE PRE-CHARGE PRESSURE IF THERE HAS 
BEEN A REDUCTION OF THE PUMP CYCLE TIME OR THE PRE-
CHARGE  PRESSURE  COMPARED  TO  ITS  INITIAL  SETTING.  
THIS  IS  BECAUSE  REDUCTION  IN  PUMP  CYCLE  TIME  CAN 
RESULT FROM LOSS OF TANK AIR PRESSURE WHICH IN TURN 
CAN MEAN THERE MAY BE INTERNAL CORROSION AND ANY 
RE-PRESSURIZATION  OR  ADDITIONAL  PRESSURE  COULD 
RESULT  IN  RUPTURE  OR  EXPLOSION,  AND/OR  PROPERTY 
DAMAGE. 

MAXIMUM WORKING PRESSURES.  

Every well 

tank  is  air  tested  to  125  psig,  the  maximum 

working pressure for the well tank line.  Should pressures exceed 
125 psig, proper selection and sizing of an ASME constructed well 
tank should be made.

RELIEF VALVE REQUIRED

.  A relief valve should 

be  installed  which  is  set  to  open  at    excessive 

pressures  (75  psig  or  more).    This  will  protect  the  well  tank  and 
other system components should the pressure switch malfunction 
and fail to shut the pump off.  The relief valve should be installed 
at the connection of the well tank to the system piping and have 
a discharge equal to the pump’s capacity at 75 psig. At least once 
every  3  years  or  if  discharge  is  present,  a  licensed  contractor 
should  inspect  the  temperature  and  pressure  relief  valve  and 
replace  if  corrosion  is  evident  or  the  valve  does  not  function. 
FAILURE TO INSPECT THIS VALVE AS DIRECTED COULD RESULT 
IN  UNSAFE  TEMPERATURE  OR  PRESSURE  BUILD-UP  WHICH 
CAN RESULT IN PRODUCT FAILURE, SERIOUS INJURY OR DEATH 
AND/OR SEVERE PROPERTY DAMAGE AND VOID THE PRODUCT 
WARRANTY.

For your safety, the information in this manual 
must  be  followed  to  minimize  the  rise  of 

electric  shock,  property  damage  or  personal  injury.    Properly 
ground to conform with all governing codes and ordinances 

Do not use this tank for chemicals, solvents, petroleum products, 
acids,  or  any  fluids  other  than  potable  water.  This  can  cause 
premature failure due to corrosion.

Make sure that the pressure switch in your well system is set low 
enough  to  shut  off  the  pump.  If  all  of  the  faucets  and  valves  are 
closed  in  your  plumbing  system  and  the  pressure  switch  setting 
is too high, the pump can run continuously without moving water 
through the system. This could damage or burn out the pump.

CALIFORNIA  PROPOSITION  65  WARNING!

  

This product contains a chemical known by the 

State  of  California  to  cause  cancer  and  to  cause  birth  defects  or 
other reproductive harm. (California Installer/Contractor - California 
law requires that this notice be given to consumer/end user of this 
product.)  For  more  information:    www.waterworkerdiy.com/
prop65.htm

Summary of Contents for HT14B

Page 1: ...r performance d If you have a jet pump remove the fittings and plug the openings where the vacuum or air lines and air volume controls connect to the pump or piping If not removed and plugged they can...

Page 2: ...the new tank cross unit NOTE If you are re using the tank cross assembly from the old tank skip to Step III 1 If you are using new parts for the tank cross assembly remove the new tank cross pressure...

Page 3: ...from the factory Release or add air to adjust the pressure properly If the charge is too high release some air by pressing down on the pin inside the air valve If the charge is too low pump it up usi...

Page 4: ...sional regarding any steps you may wish to take to safely disinfect your home s plumbing system DANGER EXPLOSION HAZARD WHEN THE WELL TANK HAS BEEN IN SERVICE AND A CHANGE TO A HIGHER PRE CHARGE PRESS...

Page 5: ...a WATER WORKER authorized distributor or retailer more than 30 days after expiration of the applicable warranty time period described in this Warranty this Warranty also does not cover repair or repla...

Page 6: ...pe jet enlevez les raccords et bouchez les ouvertures l o la tuyauterie vide ou air comprim et l o les commandes de volume d air se raccordent la pompe ou la tuyauterie S ils ne sont pas enlev s et le...

Page 7: ...ape II assemblez le nouveau bloc croisillon du r servoir REMARQUE si vous r utilisez le bloc croisillon de l ancien r servoir passez l tape III 1 Si vous utilisez de nouvelles pi ces pour le bloc croi...

Page 8: ...ez ou ajoutez de l air pour bien ajuster la pression Si cette charge est trop lev e laissez chapper un peu d air en appuyant sur la broche l int rieur du robinet d admission d air Si la charge n est p...

Page 9: ...suivre pour d sinfecter s curitairement votre plomberie r sidentielle DANGER RISQUE D EXPLOSION LORSQUE LE R SERVOIR POUR PUITS A T EN SERVICE ET QU UN CHANGEMENT UNE PRESSION DE PR CHARGE SUP RIEURE...

Page 10: ...R un distributeur ou un d taillant autoris WATER WORKER plus de 30 jours apr s l expiration de la p riode de garantie d crite dans la pr sente garantie La pr sente garantie ne couvre pas les co ts de...

Page 11: ...da ar el sistema y afectar el rendimiento d Si tiene una bomba de chorro quite los accesorios y tape las aperturas donde las l neas de vac o o aire y los controles del volumen de aire se conectan con...

Page 12: ...aso II Monte la unidad cruzada del tanque nuevo NOTA Si vuelve a usar el ensamblaje cruzado del tanque viejo vaya al paso III 1 Si usa piezas nuevas para el ensamblaje cruzado del tanque saque el cruc...

Page 13: ...tanque se env a de f brica Libere o agregue aire para ajustar la presi n de forma adecuada Si la carga es demasiado alta libere una parte del aire presionando hacia abajo el perno dentro de la v lvula...

Page 14: ...a su plomero profesional local acerca de los pasos que puede tomar para desinfectar de forma segura el sistema de tuber as de su hogar PELIGRO PELIGRO DE EXPLOSI N SI SE HA REALIZADO EL SERVICIO T CN...

Page 15: ...ER un minorista o un distribuidor autorizado de WATER WORKER despu s de los 30 d as del per odo de tiempo de vigencia de la garant a descrita aqu Esta garant a tampoco cubre los costos de reparaci n n...

Page 16: ...16...

Reviews: