background image

-1-

What You’ll Need

Before You Start

Always  be  sure  to  equip  your  well  system  with  a  proper  Pressure 

Relief Valve. This should be capable of discharging the full output of 

the pump at or below the maximum working pressure of the lowest 

rated  component  in  the  system.  See  the  owner’s  manual  for  your 

pump for output information. This is vital for safe operation of the well 

system. 

THIS PRODUCT COMES WITH A 5 YEAR WARRANTY. SEE 

WATER WORKER LIMITED WARRANTY FOR DETAILS.

READ CAREFULLY THE PRODUCT INSTALLATION, 

OPERATING  AND  MAINTENANCE  MANUAL.  

FAILURE  TO  FOLLOW  THE  INSTRUCTIONS  AND  WARNINGS  IN 

THE  MANUAL  MAY  RESULT  IN  SERIOUS  OR  FATAL  INJURY  AND/OR 

PROPERTY  DAMAGE,  AND  WILL  VOID  THE  PRODUCT  WARRANTY.  

THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED PROFESSIONAL.  

FOLLOW  ALL  APPLICABLE  LOCAL  AND  STATE  CODES  AND 

REGULATIONS,  IN  THE  ABSENCE  OF  SUCH  CODES,  FOLLOW  THE 

CURRENT  EDITIONS  OF  THE  NATIONAL  PLUMBING  CODE  AND 

NATIONAL ELECTRIC CODE, AS APPLICABLE.

THIS IS THE SAFETY ALERT SYMBOL.  IT IS USED TO ALERT YOU 

TO  POTENTIAL  PERSONAL  INJURY  AND  OTHER  HAZARDS.  

OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL 

TO REDUCE THE RISK OF PERSONAL INJURY AS WELL AS PROPERTY 

DAMAGE.

IMPORTANT GENERAL SAFETY INFORMATION - ADDITIONAL SPECIFIC 

SAFETY ALERTS APPEAR IN THE FOLLOWING INSTRUCTIONS.

Failure to utilize a properly sized well tank will result 

in excessive strain on the pump and may ultimately 

lead to product failure, leaking or flooding or property damage.

For  your  safety,  the  information  in  this  manual 

must be followed to minimize the rise of electric 

shock,  property  damage  or  personal  injury.    Properly  ground  to 

conform with all governing codes and ordinances.

1.  If you are installing an entirely new well system, follow Steps II, 

III, IV and V. Skip Step I, since you are not removing an existing 

tank. However, make sure that the power is turned off before 

you  hook  up  the  pressure  switch  to  the  household  wiring.  If 

you  are  in  any  doubt  about  working  with  electricity,  call  a 

licensed electrician.

2.  If  you  are  replacing  a  plain  steel  tank  with  this  Water  Worker 

diaphragm tank:

a.  A  diaphragm  tank  is  pressurized  with  air  at  the  factory  (at  a 

pressure  close  to  that  of  a  car  tire).  For  this  reason,  it  will  be 

smaller than the plain steel tank, even though both tanks deliver 

the same amounts of pressurized water. Because of this, you may 

have to adjust the piping to reach the new connections.

b.  Install a pressure relief valve at the tank connection to ensure the 

safety of the system.

c.  If  you  have  a  deep  well  submersible  pump,  remove  all  the  air 

charging  devices  from  the  well  system  (snifter  valves,  bleeder 

orifices,  vacuum  lines  and  connection).  Then  plug  the  holes 

where  these  devices  were  located  (see  your  owner’s  manual 

for location of these devices). These devices are not needed for 

pre-charged  tanks,  and  if  they  are  not  removed  and  the  holes 

plugged, air can get into the well system, cause surges, damage 

the system, and impair performance.

d.  If  you  have  a  jet  pump,  remove  the  fittings  and  plug  the 

openings where the vacuum or air lines and air volume controls 

connect  to  the  pump  or  piping.  If  not  removed  and  plugged, 

they  can  allow  air  into  the  pipes  which  can  damage  the  well 

system and impair performance.

e.  In addition to the above, follow Steps I through V.
3.  If you are replacing a diaphragm or bladder style tank with this 

Water Worker diaphragm tank:

a.  If the two tanks are the same size, follow Steps I through V.
b.  If they are different sizes, follow Steps I through V and also adjust 

the piping as necessary to accommodate the new size.

4.  It  is  good  practice  to  replace  the  pressure  gauge  and  the 

pressure  switch  whenever  you  replace  an  old  tank.  Of  course, 

you  can  re-use  the  tank  cross  assembly  if  you  are  replacing  a 

diaphragm tank with another diaphragm tank (including the tank 

cross, pressure gauge, pressure switch, pressure relief valve, pipe 

nipple and drain).

a.  If you do re-use a tank cross assembly, skip Step II. In this case, 

make sure that the tank is installed as closely as possible to the 

pressure switch. This will make the system operate as efficiently 

as possible.

b.  If  you  replace  the  tank  cross  assembly  with  new  parts  when 

you  install  the  new  tank,  complete  all  of  the  steps  in  these 

instructions, Steps I through V.

RELIEF VALVE REQUIRED.

  A relief valve should 

be  installed  which  is  set  to  open  at    excessive 

pressures (75 psig or more).  This will protect the well tank and other 

system  components  should  the  pressure  switch  malfunction  and 

fail to shut the pump off.  The relief valve should be installed at the 

connection of the well tank to the system piping and have a discharge 

equal to the pump’s capacity at 75 psig. At least once every 3 years 

or  if  discharge  is  present,  a  licensed  contractor  should  inspect  the 

temperature  and  pressure  relief  valve  and  replace  if  corrosion  is 

evident  or  the  valve  does  not  function.  FAILURE  TO  INSPECT  THIS 

VALVE  AS  DIRECTED  COULD  RESULT  IN  UNSAFE  TEMPERATURE  OR 

PRESSURE  BUILD-UP  WHICH  CAN  RESULT  IN  PRODUCT  FAILURE, 

SERIOUS  INJURY  OR  DEATH  AND/OR  SEVERE  PROPERTY  DAMAGE 

AND VOID THE PRODUCT WARRANTY.

5.   Always  make  sure  that  you  equip  your  well  system  with  an 

appropriate  pressure  relief  valve.    Whether  you  are  re-using  a 

tank  cross  assembly  or  assembling  a  new  one,  check  to  make 

sure  that  the  assembly  includes  a  pressure  relief  valve  that  is 

capable of discharging the full output of the pump at or below 

the maximum working pressure of the lowest rated component 

in the system. See the owner’s manual for your pump for output 
information. This is vital for safe operation of the system.

INSTALLATION MANUAL FOR VERTICAL WELL SYSTEM TANKS

Models HT14B, HT20B, HT30B, HT32B, HT44B, HT62B, HT86B and HT119B

 

Keep this manual with the tank for future reference.

Part #: 9015-376 (07/12)

Recommended Tools

Adjustable Wrench
Adjustable Pliers
Pipe Wrench
Hacksaw

Screwdriver
Tape Measure
Tire Pressure Gauge

Tank Water Connection Size 1" NPTF
Pressure Gauge
Relief Valve
Check Valve

Drain Valve
Pressure Switch
Tank Cross (10" Lx1" NPTM)
Teflon

®

 Tape

Additional Parts Required (Not Included)

Summary of Contents for HT14B

Page 1: ...r performance d If you have a jet pump remove the fittings and plug the openings where the vacuum or air lines and air volume controls connect to the pump or piping If not removed and plugged they can...

Page 2: ...the new tank cross unit NOTE If you are re using the tank cross assembly from the old tank skip to Step III 1 If you are using new parts for the tank cross assembly remove the new tank cross pressure...

Page 3: ...from the factory Release or add air to adjust the pressure properly If the charge is too high release some air by pressing down on the pin inside the air valve If the charge is too low pump it up usi...

Page 4: ...sional regarding any steps you may wish to take to safely disinfect your home s plumbing system DANGER EXPLOSION HAZARD WHEN THE WELL TANK HAS BEEN IN SERVICE AND A CHANGE TO A HIGHER PRE CHARGE PRESS...

Page 5: ...a WATER WORKER authorized distributor or retailer more than 30 days after expiration of the applicable warranty time period described in this Warranty this Warranty also does not cover repair or repla...

Page 6: ...pe jet enlevez les raccords et bouchez les ouvertures l o la tuyauterie vide ou air comprim et l o les commandes de volume d air se raccordent la pompe ou la tuyauterie S ils ne sont pas enlev s et le...

Page 7: ...ape II assemblez le nouveau bloc croisillon du r servoir REMARQUE si vous r utilisez le bloc croisillon de l ancien r servoir passez l tape III 1 Si vous utilisez de nouvelles pi ces pour le bloc croi...

Page 8: ...ez ou ajoutez de l air pour bien ajuster la pression Si cette charge est trop lev e laissez chapper un peu d air en appuyant sur la broche l int rieur du robinet d admission d air Si la charge n est p...

Page 9: ...suivre pour d sinfecter s curitairement votre plomberie r sidentielle DANGER RISQUE D EXPLOSION LORSQUE LE R SERVOIR POUR PUITS A T EN SERVICE ET QU UN CHANGEMENT UNE PRESSION DE PR CHARGE SUP RIEURE...

Page 10: ...R un distributeur ou un d taillant autoris WATER WORKER plus de 30 jours apr s l expiration de la p riode de garantie d crite dans la pr sente garantie La pr sente garantie ne couvre pas les co ts de...

Page 11: ...da ar el sistema y afectar el rendimiento d Si tiene una bomba de chorro quite los accesorios y tape las aperturas donde las l neas de vac o o aire y los controles del volumen de aire se conectan con...

Page 12: ...aso II Monte la unidad cruzada del tanque nuevo NOTA Si vuelve a usar el ensamblaje cruzado del tanque viejo vaya al paso III 1 Si usa piezas nuevas para el ensamblaje cruzado del tanque saque el cruc...

Page 13: ...tanque se env a de f brica Libere o agregue aire para ajustar la presi n de forma adecuada Si la carga es demasiado alta libere una parte del aire presionando hacia abajo el perno dentro de la v lvula...

Page 14: ...a su plomero profesional local acerca de los pasos que puede tomar para desinfectar de forma segura el sistema de tuber as de su hogar PELIGRO PELIGRO DE EXPLOSI N SI SE HA REALIZADO EL SERVICIO T CN...

Page 15: ...ER un minorista o un distribuidor autorizado de WATER WORKER despu s de los 30 d as del per odo de tiempo de vigencia de la garant a descrita aqu Esta garant a tampoco cubre los costos de reparaci n n...

Page 16: ...16...

Reviews: