CK and EQ Manual
Page 17
OEM Filter System Setup
In OEM Filter System Setup the OEM chooses the time for the cycles selected in OEM Cycle Sequence and specifies other
operating parameters for the system. The upper and lower limits of the allowable values for the cycles are as follows:
Since no time is associated with the END cycle, the END cycle will not appear in the OEM Filter System Setup sequence.
STEP 1F
STEP 2F
STEP 3F
STEP 4F
STEP 5F
Step 1F – Press NEXT and
▼
simultaneously for 3 seconds and release. If screen in Step 2F does not
appear in 5 seconds the lock on the valve is activated. To unlock press
▼
, NEXT,
▲
, and CLOCK in
sequence, then press NEXT and
▼
simultaneously for 3 seconds and release.
Step 2F – Choose FILTERING using
▼
or
▲
. Press NEXT to go to Step 3F. Press REGEN to exit
OEM Filter System Setup.
Step 3F – Select the time for the first cycle (which in this example is BACKWASH) using
▼
or
▲
.
Press NEXT to go to Step 4F. Press REGEN to return to previous step.
Step 4F – Select the time for the second cycle (which in this example is DRAW) using
▼
or
▲
. Press
NEXT to go to Step 5F. Press REGEN to return to previous step.
Step 5F – Select the time for the third cycle (which in this example is RINSE) using
▼
or
▲
. Press
NEXT to go to Step 6F. Press REGEN to return to previous step.
Cycle Options
Units
Lower/Upper Limit
Backwash
Minutes
1 to 120
Rinse (fast)
Minutes
1 to 120
Regenerant Draw DN (combination of regenerant and slow rinse) Minutes
1 to 180
Fill for all valves except WS2
Liters
0.2 to 76.00
Fill for WS2 valves
Minutes
0.1 to 99
Service
Minutes
1 to 480