Page 10
CK and EQ Manual
STEP 5CS
Step 5CS – Set Auxiliary Drive Output (MAV only) to operate in one of three modes:
• Set TIME: Allows Auxiliary MAV to switch positions at a set time in relation to the start of
regeneration for a preset duration, independently of the actual regeneration status.
• Set SEPARATE SOURCE: Allows Auxiliary MAV to switch positions before the start of
regeneration and then switch back at the end of regeneration.
• Set OFF: Deactivates this output.
Only use Clack Motorized Alternating Valves (MAV) with these selections. Clack No Hard Water
Bypass Valves (1” or 1.25” V3070FF or V3070FM) are not designed to be used with the “TIME” or
“
SEPARATE SOURCE
” modes.
Press NEXT to go to Step 6CS. Press REGEN to return to previous step.
Displays if TIME
is selected
Displays if SEPARATE SOURCE
is selected