Page 14
CK and EQ Manual
STEP 6S
Step 6S – Select the kg for the fourth cycle (which in this example is FILL) using
▲
or
▼
. When 2.0
is selected in Step 2CS, FILL is in minutes. If 1.5 is selected in Step 2CS, setting the last step of the
OEM Cycle Sequence determines if the value here is kg or minutes. Press NEXT to go to Step 7S. Press
REGEN to return to previous step.
STEP 7S
Step 7S –Set System Capacity using
▲
or
▼
. See chart. The System Capacity setting should be based on the
volume of resin and kg of salt fill set in Step 6S. The system capacity
and hardness levels entered are used to determine the Volume Capacity.
Press NEXT to go to Step 8S. Press REGEN to return to previous step.
STEP 8S
Step 8S – Set Regeneration Trigger using
▲
or
▼
. If value is set to:
• “AUTO” capacity will be automatically calculated and reserve capacity will be automatically estimated;
• “OFF” regeneration will be based solely on the day override set (see Installer Display Settings Step 3I); or
• a number, regeneration initiation will be based off the value specified.
If “OFF” or a number is used, hardness display will not be allowed to be set in Installer Display Settings Step 2I.
If “OFF” is selected, Regeneration Time is automatically “Delayed”, so Step 9S will not appear.
See Setting Options Table for more detail. Press NEXT to go to Step 9S. Press REGEN to return to previous step.
STEP 9S
Step 9S – Set Regeneration Time Options using
▲
or
▼
. If value is set to:
• “DELAYED REGEN” means regeneration will occur at the preset time;
• “IMMEDIATE REGEN” means regeneration will occur immediately when the volume capacity reaches 0 (zero);
or
• “BOTH” means regeneration will occur at one of the following:
— the preset time when the volume capacity falls below the reserve or the specified number of days between
regenerations is reached whichever comes first; or
— immediately after 10 minutes of no water usage when the volume capacity reaches 0 (zero).
“DELAYED REGEN” is the default if Step 4CS is set to VALVE A or VALVE B, and “BOTH” will not be
available.
“IMMEDIATE REGEN” is the default if Step 2SC is set to 1.0T, and “BOTH” is not available.
This step will not appear if Step 8S is set to OFF or Step 4CS is set to “SYSTEM CONTROLLER”.
See Setting Options Table for more detail. Press NEXT to go to Step 10S. Press REGEN to return to previous step.
Step 10S: Set Relay 1 operation using
▲
or
▼
. The choices are:
• Set REGEN TIME: Relay activates after a set time at the beginning of a regeneration and then deactivates after
a set period of time. The start of regeneration is defined as the first backwash cycle or Regenerant Draw UP (1”
only) or DN, which ever comes first.
• Set VOLUME: Relay activates after a set number of liters have been used while in service and then deactivates
after a set period of time or after the meter stops registering flow, whichever comes first.
• Set REGEN VOLUME: Relay activates after a set number of liters have been used while in service or during
regeneration and then deactivates after a set period of time or after the meter stops registering flow, whichever
comes first.
• Set OFF: If set to Off, Steps 11S and 12S will not be shown.
Press NEXT to go to Step 11S. Press REGEN to return to previous step.
STEP 10S
Setting Units Limits
Default
PPM
kg
0.10-200
1.50
°fH
m³
1-6000
160 m³
°dH
m³
1-6000
80 m³