Users Manual WG13 Alarm & Keypad 04 04 2022
The Smoke Alarm is in the working mode after installation, with the LED flashing once for
every 45 seconds. When it detects smoke, the alarm will sound until the smoke is cleared from
the detector.
An SMS will be sent to all numbers listed in your
“Alarm SMS number” list. The SMS will advise
what sensor has been triggered.
A pre-recorded phone call will be made to the number(s) saved in your “Alarm Call number”
list advising them of the alarm being set off in line with the calls protocol, a call will be made
to the first person on the calls list and if unanswered, the second number and so on until it has
reached the redial limit you have set in the app under settings.
Press the testing button to trigger the alarm signal, the alarm will sound, the LED flashes fast
and release the wireless signals. You can also use the smoke method to test the detector.
Testing is required regularly to make sure the smoke alarm is working correctly.
For installation instructions go to our Quick Set Up Guide
Notes.
1. This device must be paired with our base station to operate.
2. Do not install near the areas such as doors, windows, fans etc, where the air flows which
would affect the sensitivity; High humidity areas such as bathrooms, nor high temperature
places such as attic are unsuitable. The temperature should be-10°C to +50°C.
3. Please clean the alarm with a soft brush every six months to ensure the sensitivity and the
life of the product. Remove the battery before cleaning.
4. Changes in environmental conditions, or tampering can affect the performance of this
product. Users are advised to take all necessary precautions for his/her safety and the
protection of the property.
Specifications.
Working Voltage:
9V alkaline battery or carbon-zinc battery
Standby Current:
<10uA
Working Current:
<40mA
Sensitivity of Smoke:
II Grade
Emission Frequency:
315MHz/ 433MHz
Emission Distance:
open > 120m
Working Temperature:
-10 °C*-+50 °C
Interface Temperature of Air:
10%-90%RH
Alarm Sound:
275dB
Outer Size:
113*45mm
Battery Life
: 1
– 2 years
Reference Standard:
EN 14604-2005