38
Mechanical and electrical design
There is a cooling fan on the MCU. The fan starts up automatically when
the heat sink reaches a temperature of approx. 65
°
C, which can arise
during extraction if the load is unfavourable or if the ambient temperature is
high. When the machine power supply is first switched on the fan operates
for a short time.
The MCU has an interlock signal input connected to a switch in the door,
which supplies the input with main voltage when the door is locked.
PCB connector/Function
X301: Serial communication
Communications between MCU and CPU. With an interface it is
possible to connect a PC for testing machine operation/functions.
X 301:2 Gnd
X 301:3 Txd
X 301:4 Rxd
X302: Input lock confirmation
An input voltage of 96-276 VAC is required to start the motor.
The function of this input is to stop/not start the motor when the door
lock is open.
Input voltage: 120 V-20 % (=96 V) - 240 V+15 % (=276 V), 50/60 Hz
Current:
Max. 0.01 A
X304: Relay output
The relay is controlled via commands from the PCU (X301). The relay is
not to be activated if communication with the PCU is lost.
Isolation voltage:
3750 V
Voltage:
250 VAC
Current:
max. 2 A
Relay connections: 1-pole, 2-way (three connections)
Connector:
X304:1
Normally open
X304:2
Normally closed
X304:3
Common
X307: Internal
This contact is used for connection of a fan for cooling the MCU.