57
Programming
Codes 91 and 92 are used to store the values for
coin slots 1 and 2. For mechanisms with only one
slot, only code 91 is used.
The values to be stored are the ratio of one coin
to the other.
For example: if the coin slots are for a 10 cent
coin and a 50 cent coin. The value 10 should be
stored under code 91, and the value 50 should be
stored under code 92.
•
Enter code 91 using the buttons which have
become number keys 9 and 1.
The display will now show 91.
•
When entering the actual value: keep the
price-programming button activated (the switch
is located under the top cover at the right front
edge). Enter the value 1 and then release the
button.
•
Enter code 92. The display will now show 92.
•
Enter the value 5.
•
Exit the service program by pressing the
service button again.
2275
2274
2276
2272
3400
70
71
72
73
74
Fig.
70
Fig.
71
Fig.
72
Fig.
73
Fig.
74
Summary of Contents for EXSM 230 S
Page 4: ......
Page 6: ......
Page 32: ...32 Mechanical and electrical design Control unit ...
Page 93: ...93 Trouble shooting If machine vibrates excessively A Tighten mounting bolts Fig 101 101 2408 ...