79
Trouble shooting
Turn the machine’s wall switch off and on again.
Start a program.
Error code returns
No error code
Unscrew the program control unit PCB. Remove
the EPROM, then refit the same one. Check that
the EPROM is turned the right way and that all
its leg connectors enter the holder correctly.
Restart the machine.
Error code 12E returns
Machine normal
Replace the EPROM. Check that the new one
has the correct program version. Restart
machine.
Error code 12E returns
Machine normal
12E
The program control unit
cannot read the program
EPROM.
Error codes which may arise on the control panel display
2316
The marking
on the
EPROM
must be to
the left.
EPROM
Faulty program control unit
PCB. Replace PCB. The old
EPROM can probably be
reused.
Old EPROM was faulty.
Temporary loss of contact or
EPROM fitted incorrectly.
Transient fault. No action
required.
Cause/Action
Error code/symptoms
Fault-finding