Extraction
During extraction, the motor speeds follow an extraction sequence which is
always the same. This extraction sequence is used for all standard
programs 991-999 for CLARUS machines.
The table shows the extraction speeds during the various phases of the
sequence, for various drum volumes.
The extraction sequence is as follows:
Phase 1.
Distribution period of 40 seconds, with imbalance
sensing. Imbalance sensing takes place during the
last 5 seconds.
Phase 2.
Extraction for 30 seconds.
Phase 3.
Extraction for 30 seconds.
Phase 4.
Extraction for 30 seconds.
Phase 5.
Extraction for remainder of the program’s total
extraction time.