1.2
Reference conditions
The output is available up to a charge air coolant temperature of max. 38°C and an air
temperature of max. 45°C. For higher temperatures, the output has to be reduced according
to the formula stated in ISO 3046-1:2002 (E).
The specific fuel oil consumption is stated in the chapter Technical data. The stated specific
fuel oil consumption applies to engines with engine driven pumps, operating in ambient
conditions according to ISO 15550:2002 (E). The ISO standard reference conditions are:
100 kPa
total barometric pressure
25°C
air temperature
30%
relative humidity
25°C
charge air coolant temperature
Correction factors for the fuel oil consumption in other ambient conditions are given in standard
ISO 3046-1:2002.
1.3
Operation in inclined position
Max. inclination angles at which the engine will operate satisfactorily.
15.0°
●
Transverse inclination, permanent (list)
22.5°
●
Transverse inclination, momentary (roll)
5.0°
●
Longitudinal inclination, permanent (trim)
7.5°
●
Longitudinal inclination, momentary (pitch)
Larger angles are possible with special arrangements.
1-2
Wärtsilä 26 Product Guide - a9 - 7 September 2016
Wärtsilä 26 Product Guide
1. Main Data and Outputs
Summary of Contents for WARTSILA 26
Page 1: ...W RTSIL 26 PRODUCT GUIDE...
Page 12: ...This page intentionally left blank...
Page 34: ...This page intentionally left blank...
Page 50: ...This page intentionally left blank...
Page 92: ...This page intentionally left blank...
Page 114: ...This page intentionally left blank...
Page 148: ...This page intentionally left blank...
Page 160: ...This page intentionally left blank...
Page 172: ...This page intentionally left blank...
Page 182: ...This page intentionally left blank...
Page 188: ...This page intentionally left blank...
Page 190: ...This page intentionally left blank...
Page 193: ......
Page 194: ......
Page 195: ......