where:
total starting air vessel volume [m
3
]
V
R
=
normal barometric pressure (NTP condition) = 0.1 MPa
p
E
=
air consumption per start [Nm
3
] See Technical data
V
E
=
required number of starts according to the classification society
n =
maximum starting air pressure = 3 MPa
p
Rmax
=
minimum starting air pressure = See Technical data
p
Rmin
=
NOTE
The total vessel volume shall be divided into at least two equally sized starting air
vessels.
8.2.4
Air filter, starting air inlet (3F02)
Condense formation after the water separator (between starting air compressor and starting
air vessels) create and loosen abrasive rust from the piping, fittings and receivers. Therefore
it is recommended to install a filter before the starting air inlet on the engine to prevent particles
to enter the starting air equipment.
An Y-type strainer can be used with a stainless steel screen and mesh size 400 µm. The
pressure drop should not exceed 20 kPa (0.2 bar) for the engine specific starting air
consumption under a time span of 4 seconds.
8-6
Wärtsilä 26 Product Guide - a9 - 7 September 2016
Wärtsilä 26 Product Guide
8. Compressed Air System
Summary of Contents for WARTSILA 26
Page 1: ...W RTSIL 26 PRODUCT GUIDE...
Page 12: ...This page intentionally left blank...
Page 34: ...This page intentionally left blank...
Page 50: ...This page intentionally left blank...
Page 92: ...This page intentionally left blank...
Page 114: ...This page intentionally left blank...
Page 148: ...This page intentionally left blank...
Page 160: ...This page intentionally left blank...
Page 172: ...This page intentionally left blank...
Page 182: ...This page intentionally left blank...
Page 188: ...This page intentionally left blank...
Page 190: ...This page intentionally left blank...
Page 193: ......
Page 194: ......
Page 195: ......