18
Warner Electric • 800-825-9050
P-2003-2 • 819-0420
o
15 . Monitor the voltage at terminals 3 and 2 or
the current at terminal 4 of terminal block TB1, as
well as the brake current on terminal 1 of
terminal block TB2 .
a . If using a sensor: As the roll diameter
decreases, the sensor voltage or current will
decrease which will cause the brake torque to
decrease, keeping the tension proportional to the
roll size .
b . If using a PLC: As the roll diameter
decreases, the analog signal from the PLC must
decrease to keep the tension proportional to the
roll size .
o
16 . After an initial run has been completed,
remove power from the system and wait
approximately 30 seconds before proceeding to
the next step .
o
17 . Remove the meter from between the sense
magnet lead to terminal 1 of terminal block TB2
and tighten the terminal screw .
o
18 . Disconnect the second voltmeter from
terminals 2 and 3 of terminal block TB1 .
o
19 . Reapply power to the control system .
o
20 . If the remote mode selector switch is used,
repeat steps 5 through 17, using the remote
mode selector switch .
Note:
If start-up and adjustment procedures do
not provide the desired results, consult the
troubleshooting section of this manual .
o
21 . Close the cover of the TCS-200-1 and latch
by tightening the screw that is provided .