Electrical Specifications
Unit Size
PB-500
PB-650
Voltage - DC
6
24
90
6
24
90
Resistance @ 20oC - Ohms
1 .36
23 .8
251 .1
1 .24
18 .3
257 .2
Current - Amperes
4 .4
1 .01
.36
4 .84
1 .31
.35
Watts
26
24
32
29
31
32
Coil Build-up - Milleseconds
84
87
93
100
105
110
Coil Decay- Milliseconds
38
35
30
50
50
50
Notes:
Build-up time equals current to approximately* 90% of steady state value and flux to 90% .
Decay time equals current to approximately* 10% of steady state value and flux to 10% .
*Approximately because current leads or lags flux by a small amount .