10
Warner Electric • 800-825-9050
P-0204-WE • 819-0485
Figure 9
Figure 10
D. Mounting the Armature Assembly
The armature and armature hub are mounted on the
shaft with a taperlock bushing . All parts must be clean
and free from burrs and chips before assembling .
1 . Place the bushing into the hub and insert the key .
The key is a side-to-side fit and should not contact
the top of the keyway .
2 . Insert the locking setscrews into the bushing and
slide the assembly onto the shaft .
3 . Place the face of the armature approximately 1/32”
from the face of the magnet . Once this gap is set, it
will be automatically maintained throughout the life of
the unit . (Figure 10)
4 . Securely fasten the armature assembly to the shaft
by alternately tightening each setscrew . During the
tightening process the bushing should be tapped
lightly to make certain it seats-in properly .
Step 5
Tighten drive pins until shoulders of pins are against face
of armature bosses . Since threads are class No . 3 fit,
pins may seem to bind .
Step 6
Compress the retainer rings against the armature hub,
and check to see that the part is held tightly to the
armature bosses .
Note:
This position must not be disturbed during
completion of assembly . (Figure 9)