background image

För att komma till avancerade inställningar, 

TRYCK

 och 

Håll

           inne samtidigt i 5 sekunder.

TRYCK på SET

 för att navigera i menyn. Använd          för att ändra värderna. Tryck OK För att avsluta.

Display Function

Värde

Default

CL

Kalibrering av temperatur

-4 °C - + 4 °C

0

bL

Bakgrundsbelysning

1 = (AV) 2 = (PÅ) 3 = (ALLTID PÅ)

2

AF

Sensorval

A = Luftsensor       

F  =  Golvsensor    

AF = Luft 

och golv**

AF

AH

Maxvärde av temperatur för (F),

golvsensor (A) luftsensor eller (AF)

för båda

Golvsensor

(F) + 18°C - + 35°C

Luftsensor/Luft och golvsensor 

(A/AF) + 18°C - + 45°C

F = (45°C)

A = (35°C)

AF = (35°C)

FL

Minimum golvtemperatur

Golvsensor

 (F) + 5°C - + 20°C

10°C

FH

Max golvtemperatur 

Golvsensor

 (F) + 25°C - + 50°C

50°C

PS

Veckoschema vardag/helg

3 = (1-5 Block, 1 + 1)       7 = 7 dagar

3

CS

Antal program per dag

P4 = 4 Program per dag / P6 = 6 Program per dag

P4

CF

Val av °Celsius / °Fahrenheit

C = °Celsius / F = °Fahrenheit

°C

CO

Val 24hr /12hr Klocka

24h / 12h

24h

LD

Val av ampere* 

HH = (16 - 12 A), H = (11 - 8 A), L (

7 A)

H

SE

Sensorval

100 = 100K / 10 = 10K sensor 

100

För att återställa till standardväde 

TRYCK och håll

      inne i 3 sekunder när termostaten är i standardsläge

och ikonen för klocka visas,      . 

ConF

 kommer blinka, 

TRYCK OK

 för att acceptera.

* Felaktig installning av termostatens belastning kan leda till felaktig temperaturdata

** För att se aktuellt temperaturvärde när termostaten är inställd på AF (Luft och golv), Tyck och HÅLL      inne i 3

sekunder

Avancerade inställningar

Felsökning

KOD

Fel

Action

E1

Golvsensor kortsluten F eller AF

Testa sensor och byt om skadad. Mätvärde enligt följande

motstånd: 100kΩ vid 25°C, 125.5kΩ vid 20°C, 157.4kΩ vid 15°C

E2

Golvsensor ej ansluten eller trasig typ 

AF

Testa sensor och byt om skadad. Mätvärde enligt följande

motstånd: 100kΩ vid 25°C, 125.5kΩ vid 20°C, 157.4kΩ vid 15°C

E3

Luftsensor kortsluten

Byt enhet eller använd enbart golvsensor

E4

Luftsensor skadad

Byt enhet eller använd enbart golvsensor

E5

Felaktig golvssensor ansluten

Installera en 100k eller 10k golvsensor

Öppet fönsterfunktion - 

Warmup ONE har en funktion för att känna av ifall det blir ett plötsligt fall av temperatur

(1.5°C eller mer inom 3 minuter) När ett fönster öppnas kommer den att stänga av värmen för att spara energi. Värmen 

kommer slås på igen om temperaturen ökar med (1.5°C inom 30 minuter). Tryck på valfri knapp för att återgå till 

schemalaggt läge.

6

Warmup - IM - One - v1.0 2018-07-31.indd   6

31/07/2018   10:58:33

Summary of Contents for One

Page 1: ...he Warmup One requires a permanent power supply from a 30mA RCD protected circuit in accordance with the current edition of the Wiring Regulations The thermostat and its power supply should be isolated from the mains supply throughout the installation process Ensure that wires are fully inserted into the terminals with no bare wire visible and secured Any free strands should be trimmed as they cou...

Page 2: ...ating schedule mode is displayed ConF will flash PRESS OK to accept Failing to set the Heating Load correctly will reduce the accuracy of the thermostats air temperature reading To view current floor temperature when the thermostat is set to AF Air with floor limit PRESS and HOLD for 3 seconds Advanced Settings Troubleshooting Code Fault Action E1 Floor sensor short circuit in type F or AF Check t...

Page 3: ... Schedule Setting a Heating Schedule allows you to set comfort temperatures at set times throughout the day The thermostat can bet set so that MON FRI 1 5 is programmed as a block with SAT 6 and SUN 7 programmed individually Alternatively the thermostat can set so that you program each day individually see advanced settings on how to switch between schedule settings Typically when setting a 6 peri...

Page 4: ...o heating schedule mode PRESS OK Setting a Temporary Override Warmup warrants this product to be free from defects in the workmanship or materials under normal use and service for a period of 1 year from the date of purchase by the consumer If at any time during the warranty period the product is determined to be defective Warmup shall repair or replace it at Warmup s discretion If the product is ...

Page 5: ...att de sitter ordentligt åtdragna Felaktig installation kan leda till kortslutning och brand Matningsspänning 100 240 V AC 50 60 Hz Modell ONESTAT IP Klass IP21 Maxbelastning 16 A 3840 W Installationsdjup Min 35mm Dimentioner H W D 81 x 81 x 25 mm Från vägg Sensor Luft och Golv Kompabilitet eUFH Sensortyp 2 5m NTC 100K Kan utökas till max 50 m Er P Klass I Issoleringsklass II Standard EN60730 1 EN...

Page 6: ... för klocka visas ConF kommer blinka TRYCK OK för att acceptera Felaktig installning av termostatens belastning kan leda till felaktig temperaturdata För att se aktuellt temperaturvärde när termostaten är inställd på AF Luft och golv Tyck och HÅLL inne i 3 sekunder Avancerade inställningar Felsökning KOD Fel Action E1 Golvsensor kortsluten F eller AF Testa sensor och byt om skadad Mätvärde enligt ...

Page 7: ...rläge Schemalagt läge Schemalagt läge låter dig välja olika temperaturer under dagen Termostaten kan ställas in till MÅN FRE 1 5 är programmerat som ett block med Lör 6 och Sön 7 programmerat som ett speparat Alternativt kan varje dag programeras separat se Avancerade inställningar Standardinställningen vid ett 6 periodsschema kommer period 1 3 coh 5 vara påslagen värme och period 2 4 och 6 kommer...

Page 8: ...tt vanliga schema vid nästa periodstart för att avbryta avikande läge välj schemalagt läge och TRYCK OK Inställningar för tillfällig avvikelse Warmup garanterar att denna produkt är fri från defekter i utförande eller funktion under normal användning under en period av 1 år från inköpsdatum Om produkten på något sätt under garantiperioden är defekt ska Warmup reparera eller byta ut det Om produkte...

Reviews: