background image

Digital Thermostat Owners Manual 

Model: TESD22 

 

 

 

 

 

 

 

 

 

 

 

 

FEATURES 

Structure of thermostat and explanation for the keypads 

 

 

 

 

 

 

We are pleased you have selected one of our broad line of wall thermostat. 

Our products are manufactured to high quality standards and are

 

designed 

for years of service.   

Read This Before Installing Thermostat 

OPERATION 

YOUR THERMOSTAT REPLACES 

Description 

TESD22 

Heat Pump (No Aux. or Emergency Heat) 

Yes 

Heat Pump (with Aux. or Emergency Heat) 

Yes 

Standard Heat & Cooling Systems 

Yes 

Two Stage Heat & Two Stage Cool 

Yes 

Standard Heat Only Systems 

Yes 

Millivolt Heat Only Systems

– Floor or Wall 

Furnaces 

Yes 

Standard Central Air Conditioning 

Yes 

Gas or Oil Heat 

Yes 

Electric Furnace 

Yes 

Hydronic (Hot Water) Zone Heat-2 Wires 

Yes 

Hydronic (Hot Water) Zone Heat

–3 Wires 

No 

This Thermostat will NOT control 110/220Volt systems. 

IMPORTANT 

2

,

  Read  the  entire  installation  section  of  this  Owner

’s  Manual  thoroughly 

before you begin to install or operate your Thermostat.

   

This thermostat can be used for conventional or heat pump 
system,  Please  configure  the thermostat  according  to 
Configuration Menu before operation.

 

REMOVE THE MYLAR LABEL FORM THE LCD DISPLAY WINDOW. 

INSTALLATION 

3

,   

All installation is normally performed at your thermostat. 

COMPRESSOR PROTECTION

 

4

The thermostat provides a 4 minutes delay after shutting of the heating or 

cooling system before it can be restarted. This feature will prevent damage 

to your compressor caused by rapid cycling. Note that this delay also applies 

to  the  heating  system  control.  It  does  not  provide  a  delay  when  there  are 

power outages.you can select the function on or off at the configuration.

   

TEMPERATURE RANGE 

5,This  thermostat  can  be  programmed 

between  45˚F  and  95˚F  (7˚C  and 

35˚C). However, it will display room temperatures from 30˚F to 99˚F (0˚C and 
37˚C).  “HI”  will  be  displayed  if the temperature  is  higher  than  99˚F  (37˚C), 
and “LO” will be displayed if the temperature is lower than 30˚F (0˚C).This 

thermostat  will  automatically  cutoff  in  Heat  mode  if  the  temperature  rises 

above 95˚F (35˚C), and automatically cutoff in Cool mode if the temperature 
drops below 45˚F (7˚C). 

NOTE: if the thermostat measure a temperature over 99

˚F(37

), 

”HI” will be 

displayed on the LCD. if the temperature is below 32

˚F(0

). and 

”LO” will be 

displayed on the LCD. 

POWER FAILURE 

6

  Whenever the main power is interrupted or fails, the battery power 

retains and current time. This thermostat has permanent memory, although 

you will have to reset your clock when there are power outages. 

POWER SUPPLY 

7

The thermostat shall be powered by 24 VAC and with batteries as backup. 

BATTERY WARNING

 

8

Fresh  alkaline  batteries  should  provide  about  one  year  of  service. 

However,  when  the  batteries  become  drained, 

“BATT”  will  alternate  on the 

display  with  the current time. When  this message  occurs,  install  2 new  AA 

batteries, You have approximately 1 minute to change the batteries and keep 

thermostat

’s  clock.  Once  the  batteries  have  become  too  low  to  ensure 

proper  operation,  your  system  will  be  turned  off,  and  the  display  will  be 

cleared except for 

“BATT” flashing on the LCD display. 

CAUTION: 

Once only the 

“BATT” only display occurs, the thermostat is shut 

down,  and  your  system  will  no  longer  operate.  In  this  condition, 

there  is  no  temperature  control  of  your  dwelling.   

NOTE:  The 

backlight will not function when the thermostat is in low battery condition. 

NOTE:  If  you  plan  to  be  away  from  the  premises  over  30  days,  we 

recommend  that  you  replace  the  old  batteries  with  new  alkaline 

batteries prior to leaving. 

INSTALLATION 

What You Need 

This  thermostat  includes  two  #8  slotted  screws  and  two  wall  anchors  for 

mounting. To install your thermostat, you should have the following tools and 

materials. 

■ Slotted Screwdriver(s)          ■ Small Philips screwdriver            ■ Hammer 
■  Electric  drill  and  3/16”  bit      ■  Two1.5V  (AA)  size  alkaline  batteries 

(included) 

CAUTION: 

To  prevent  electrical  shock  and/or  equipment  damage,  disconnect 

electric  power  to  system  at  main  fuse  or  circuit  breaker  box  until 

installation is complete. 

Before removing wires from old thermostat's switching subbase, label each 

wire with the terminal designation it was removed from. 

1. Shut off electricity at the main fuse box until installation is complete. 

Ensure that electrical power is disconnected. 

2.  Remove  Old  Thermostat:  A  standard  heat/cool  thermostat  consists  of 

three basic parts: 

a. The cover, which may be either a snap-on or hinge type. 

b. The base, which is removed by loosening all captive screws. 

c.  The  switching  subbase,  which  is  removed  by  unscrewing  the  mounting 

screws that hold it on the wall or adaptor plate.   

3.  Remove  the  front  cover  of  the  old  thermostat.  With  wires  still  attached, 

remove  wall  plate  from  the  wall.  If  the  old  thermostat  has  a  wall  mounting 

plate, remove the thermostat and the wall mounting plate as an assembly. 

4. Identify each wire attached to the old thermostat. 

5. Disconnect the wires from the old thermostat one at a time. DO NOT LET 

WIRES FALL BACK INTO THE WALL. 

6. Install new thermostat using the following procedures. 

WARNING 

Do not use on circuits exceeding specified voltage. Higher voltage will 

damage control and could cause shock or fire hazard. Do not short out 

terminals  on  gas  valve  or  primary  control  to  test.  Short  or  incorrect 

wiring will damage thermostat and could cause personal injury and/or 

property damage.   

Selector Switches

 

Electric/Gas Switch (Fan Option) 

 

 

 

 

 

 

 

 

 

 

Figure 1. Electric/Gas Switch (Fan Option) 

This thermostat is configured from the factory to operate a heat/ cool, fossil 

fuel (gas, oil, etc.), forced air system. It is configured correctly for any system 

that DOES NOT require the thermostat to energize the fan on a call for heat. 

If  you  system  is  an  electric  heat  or  heat-pump  system  that  requires  the 

thermostat to turn on the fan on a call for heat, locate the ELEC/GAS switch 

on the back of the thermostat (see fig. 1) and switch it to the ELEC position. 

This  will  allow  the  thermostat  to  energize  the fan  immediately on  a  call  for 

heat. If you are unsure if the heating/ cooling system requires the thermostat 

to  control  the  fan,  contact  a  qualified  heating  and  air  conditioning  service 

person.  When  the  thermostat  is  configured  for  Heat  Pump,  the  thermostat 

will always power the circulator fan on a call for heat in the HEAT mode. The 

ELEC/GAS  switch  must  be  set  to  match  the  type  of  Auxiliary  heat  your 

system uses for proper operation in the EMERgency mode. 

All  wiring  diagrams  are  for  typical  systems  only.  Refer  to  equipment 

manufacturers

’ instructions for specific system wiring information. 

Attach Thermostat Base to Wall

 

1.  Remove the  packing material from  the thermostat.  Gently  pull the cover 

straight off the base. Forcing or prying on the thermostat will cause damage 

to the unit. 

2. Connect wires beneath terminal screws on base using appropriate wiring 

schematic (see figs. 2 through 4). 

3.  Place  base  over  hole  in  wall  and  mark  mounting  hole  locations  on  wall 

using base as a template. 

4. Move base out of the way. Drill mounting holes. 

5. Fasten base loosely to wall, as shown in fig. 1, using two mounting screws. 

Place  a  level  against  bottom  of  base,  adjust  until  level,  and  then  tighten 

screws.  (Leveling  is  for  appearance  only  and  will  not  affect  thermostat 

operation.) If you are using existing mounting holes, or if holes drilled are too 

large and do not allow you to tighten base snugly, use plastic screw anchors 

to secure subbase. 

6.  Push  excess  wire  into  wall  and  plug  hole  with  a  fire  resistant  material 

(such  as  fiberglass  insulation)  to  prevent  drafts  from  affecting  thermostat 

operation. 

 

 

 

 

 

 

 

 

 

 

Figure 2. Thermostat base

 

 

 

 

 

 

Figure 3 Typical wiring diagram for single transformer heat pump 

systems 

 

 

 

 

 

 

Figure 4. Typical wiring diagram for two transformer heat pump 

systems with NO safety circuits 

 

 

 

 

 

 

Figure  5.  Typical  wiring  diagram  for  two  transformer  heat  pump 

systems with safety circuits in BOTH systems 

Heat Pump Terminal Outputs 

Refer  to  equipment  manufacturers'  instructions  for  specific  system  wiring 

information. You can configure the thermostat for use with the following heat 

pump  system  types:  HEAT  PUMP  TYPE  1  1.  Single  stage  compressor 

system;  gas  or  electric  backup.  This  thermostat  is  designed  to  operate  a 

single-transformer  system.  If  you  have  a  two-transformer  system,  cut  and 

tape off one transformer. If transformer safety circuits are in only one of the 

systems,  remove  the  transformer  of  the  system  with  NO  safety  circuits.  If 

required,  replace  remaining  transformer  with  a  75VA  Class  II  transformer. 

After  disconnecting  one  transformer,  the  two  commons  must  be  jumpered 

together. 

Use  the  terminal  output  information  below  to  help  you  wire  the  thermostat 

properly  for  your  heat  pump  system.  After  wiring,  see  CONFIGURATION 

section for proper thermostat configuration. 

THERMOSTAT TERMINALS (HEAT PUMP) 

SYSTEM 

Heat Pump 1 

Heat Pump 2 

Malfunction 

C* 

24 Volt(Common) 

24 Volt Emergency (hot) 

E/W1 

Emergency Mode 1st stage 

W2 

HP 1 and Emergency 2nd stage 

Y1 

Heat and Cool mode 1st stage (compressor) 

Y2 

No output 

2nd stage compressor 

 

Blower/Fan Energized on call for Heat and Cool 

Set GAS/ELEC switch for Emergency mode 

Energized in Cool Mode 

Energized in Heat Emergency mode 

 

 

 

 

 

 

Figure 5. Typical wiring diagram for single transformer multi-stage 

systems 

CHECK THERMOSTAT OPERATION

 

Note: 

To  prevent  static  discharge  problems,  touch  side  of  thermostat  to 

release static build-up before touching any keys. 

If  at  any  time  during  testing  your  system  does  not  operate  properly, 

contact a qualified serviceperson.

 

Fan Operation 

If  your  system  does  not  have  a  G  terminal  connection,  skip  to  Heating 

System. 

1. Turn on power to system. 

2. Move FAN switch to ON position. The blower should begin to operate. 

3. Move FAN switch to AUTO position. The blower should stop immediately 

Heating System

 

1. Move system switch to heat mode. If the auxiliary heating system has a 

standing pilot, be sure to light it. 

2. Press to adjust thermostat setting to 1

  above room    temperature. The 

heating system  should begin to 

operate. The display should show “STG1”. 

However,  if  the  setpoint  temperature  display  is  flashing,  the  compressor 

lockout feature is operating (see Configuration menu, item 5). 

3. Adjust temperature setting to 3° above room temperature. If your system 

configuration  is  set  at  MS2,  HP2  or  HP1,  the  auxiliary  heat  system  should 

begin to operate and the 

display should show “STG1+2”. 

4.  Press  to  adjust  the  thermostat  below  room  temperature.  The  heating 

system should stop operating. 

Emergency System

 

EMER bypasses the Heat Pump to use the heat source wired to terminal E 

on the thermostat. EMER is typically used when compressor operation is not 

desired, or you prefer back-up heat only. 

1.  Press  SYSTEM  switch  to  select  Heat  mode.  then  press  EMER  key.. 

“EMER” will show on the display. 

2.  Press  to  adjust  thermostat  setting  above  room  temperature.  The  Aux. 

heating system will begin to 

operate. The display will show “STG1” “EMER” 

to indicate that the Aux. system is operating. 

3. Adjust temperature setting to 2°C above room temperature. The auxiliary 

heat system should begin to operate and the 

display should show “STG1+2”. 

4. Press to adjust the thermostat below room temperature. The Aux. heating 

system should stop operating. 

Cooling System 

1. Move SYSTEM switch to select the Cool mode. 

2.  Press  to  adjust  thermostat  setting  below  room  temperature.  The  blower 

TIME

ENER

EMER

RUN

Measures and displays
heating and cooling system

operating time for Today,
Yesterday,This Week,Last
Week,or Total.By monitoring
your energy usage,you can
program the thermostat to
optimize energy savings.

For entering Time

Returns display to current time and temperature.

EMER Mode

Reversing 
  Valve 
Energized in 
Cool Mode

Reversing 
  Valve 
Energized in
 Heat, 
Emergency 
  Mode

2nd Stage
Compressor

Fan
Relay

Emergency
Heat
Relay

Compressor
Contactor

Aux 
Heat
Relay

Hot
120 VAC

Neutral

    TRANSFORMER
(Class 

 Current Limited)

24 VAC

      

Limit or Safety
 Switches

Reversing 
  Valve 
Energized in 
Cool Mode

Reversing 
  Valve 
Energized in
 Heat, 
Emergency 
  Mode

2nd Stage
Compressor

Fan
Relay

Emergency
Heat
Relay

Compressor
Contactor

Aux 
Heat
Relay

Hot
120 VAC

Neutral

 

    

  

TRANSFORMER

(Class    Current Limited)

24 VAC

Reversing 
  Valve 
Energized in 
Cool Mode

Reversing 
  Valve 
Energized in
 Heat, 
Emergency 
  Mode

2nd Stage
Compressor

Fan
Relay

Emergency
Heat
Relay

Compressor
Contactor

Aux 
Heat
Relay

Limit or
 Safety
 Switches

Limit or
 Safety
 Switches

HOT

120 VAC

   Heat Pump Transformer
(Class     Current Limited)

24 VAC

Limit or Safety
 Switches

COMMON

HOT

120VAC

Auxiliary
 Heating 
Transformer
(Class 
Current Limited)

24VAC

Limit or
 Safety
 Switches

      NEUTRAL

      NEUTRAL

COMMON

     

The accessory relay scheme 
is required when safety
circuits ezist in both systems

Reversing 
  Valve 
Energized in 
Cool Mode

Reversing 
  Valve 
Energized in
 Heat, 
Emergency 
  Mode

Fan
Relay

Heat
Relay
Stage 1

Compressor
Contactor
Stage 1

    

Heat
Relay
Stage 2

Compressor
Contactor
Stage 2

Returns display to current 
time and temperature.

Measures and displays
heating and cooling system
operating time for Today,
Yesterday,This Week,Last
Week,or Total.

For entering Time

EMER Mode

EMER

TIME

TEMP

FAN

SYSTEM

OFF

COOL

HEAT

ON

AUTO

Front Door: 
         Cover keys Open with one finger from left or right.

Heat,Cool,and Off.

Selector switch for

System Switch:

operation.

or Continuous fan

switch for Automatic

Fan Switch: Fan

functions.

Time,Program,and Span

and decreasing selections in the

setting. Also used for increasing

changing the Temperature

Up and Down Key:Key for

ENER

RUN

/return

Backlight key

Program Number,and other feature information

LCD Display:Shows Time,Day,Temperature,

as required.

K2

Elec-Gas

Switch

GAS

ELE

C

Mounting
Hole

Mounting
Hole

Reviews: