34
warmhaus.com
3.1.5. Operation in Summer Mode
Combi boiler only operates for heating the domestic
hot water in this mode.. In order to switch to tap water
position;
Domestic Hot Water
Adjustment at Winter
Position;
You can adjust the hot tap water
temperature value between
35 –60 °C with (6) and (7)
numbered buttons under the
RESET button. Screen lights
during temperature change, °C
and
symbol flashes besides
the DHW temperature value.
Screen light turns off after
adjustment.
At that position, you can
adjust the Domestic Hot Water
temperature between 35 – 60
°C with (7)
and (8)
numbered buttons below the
RESET button.
3.1.4. Operation in Winter Mode
At that position, combi boiler operates both for heating
the environment and providing Domestic Hot Water.
Radiator (CH) temperature adjustment is made with (3)
and (4) numbered buttons in Figure 47, Domestic Hot
Water temperature adjustment is made with (6) and (7)
numbered buttons and this temperature is indicated with
(9) numbered indicator for Radiator (CH) and with (11)
numbered indicator for Domestic Hot Water.
In such case, combi boiler initially
gets into Radiator position,
its symbol
flashes on the
left bottom corner of screen
and tap symbol
is seen at
right bottom corner. A digital manometer indicating the
installation pressure is located at lower middle section
of the screen and also existing radiator installation
temperature is seen on the screen at the same time and
screen light is turned off.
When combi boiler is started, flame modulation symbol is
seen at the middle section of the screen. At that position,
you can increase
and decrease
the temperature
with CH temperature adjustment buttons (see. Figure
40) (3) between 35 – 80 °C, screen lights when buttons
are pressed and °C symbol
flashes besides the CH
temperature value.
If you are starting the combi for
the first time hold
MODE
button,
and release the button after the
cycle
is completed on the
screen, initially combi switches
to radiator position, its symbol
will flash on left top corner
of the screen existing radiator
installation temperature and
screen light will turn off.
In order to switch to tap water
position, hold
MODE
button
and release the button after
completion of cycle on the
screen. At that position, symbol
flashes at right bottom
corner of the screen and existing
tap water temperature will be
seen on the screen and screen
light will turn off.
{If you have a floor heating system, as our
Authorized Service adjust your combi for
“Low Temperature Operation”
, maximum
temperature shall be limited with the
Radiator (CH) temperature adjustment button (3) (e.g.
maximum 47 °C)}.
When the combi boiler is started
for the first time, screen displays
nG letter and then a number
(for instance 25) indicating kW
power of the device.
Then, OFF letter is displayed,
and screenlight is closed. Now,
combi boiler is at STANDBY
position. The temperature value
when electricity is supplied to
the device is the temperature
value of water in the installation
Screen lights during temperature change, °C symbol
flashes besides the DHW temperature value. Adjustment
value is confirmed after screen light turned off following
the adjustment.