3
warmhaus.com
INDEX
1. DEAR WARMHAUS CUSTOMER ...............................................................................................................4
1.1. GENERAL WARNINGS .............................................................................................................................................4
1.2. GENERAL WARRANTY CONDITIONS................................................................................................................4
1.3. BOILER GAS CATEGORIES & DESTINATIONS ................................................................................................6
1.4. GAS LEAKAGES .......................................................................................................................................................8
2. INSTALLATION PERSONNEL SECTION ...................................................................................................9
2.1. CONTENTS OF PACKING BOX .............................................................................................................................9
2.2. COMBI BOILER INSTALLATION RULES ..........................................................................................................10
2.2.1. General Rules for Installation Places of Combi Boilers ............................................................................10
2.2.2. Places Not Suitable for Installing Hermetical Combi Boilers.................................................................10
2.2.3. Wall Installation of Combi Boiler and Selecting the Installation Place ...............................................10
2.2.4. Dimensions and Connections .......................................................................................................................... 11
2.2.5. Natural Gas and LPG Connection (Device Category I
2H
, II
2H3P
) ............................................................. 11
2.2.6. Flammable Gas Quality ..................................................................................................................................... 11
2.2.7. In Case of Using LPG Tank ................................................................................................................................ 11
2.2.8. In Case of Using Bottled Gas ........................................................................................................................... 11
2.2.9. Filling the siphon for Condensation Line .....................................................................................................12
2.2.10. Installation at Partially Protected Exteriors ...............................................................................................12
2.2.11. Electrical Connections ...................................................................................................................................... 13
2.2.12. Optional Controls: Room Thermostat, Outside Sensor and Others ................................................... 13
2.3. HYDRAULIC INSTALLATION RULES................................................................................................................ 15
2.3.1. Radiator and DHW Installations ...................................................................................................................... 15
2.3.2. Filling/Emptying Radiator Installation ......................................................................................................... 15
2.3.3. Circulation Pump .................................................................................................................................................17
2.4. CONTROLS FOR INITIAL OPERATION OF COMBI BOILER ...................................................................... 18
2.5. COMBI COMPONENTS ......................................................................................................................................... 18
2.6. COMBI BOILER FLUE CONNECTIONS ............................................................................................................ 19
2.6.1. Exhaust Gas Flue Pipe Set and Accessories Connection ....................................................................... 19
2.6.2. BOILER FLUE CONNECTION TYPES ............................................................................................................. 19
2.6.3. Peripheral Distances of Flue Output Connections ...................................................................................22
2.6.4. Installation with Horizontal Flue Sets ..........................................................................................................22
2.6.5. Installation with Vertical Flue Sets (Ø60/100 mm) .................................................................................25
2.6.6. Twin Flue Kits Ø 80/80 Flue Type Use ....................................................................................................... 26
2.6.7. Recommendations of Plume Kit Installation .............................................................................................. 31
3. USER’S SECTION......................................................................................................................................32
3.1. GENERAL WARNINGS FOR USER ....................................................................................................................32
3.1.1. Use of Combi Boiler .............................................................................................................................................32
3.1.2. Selection of On/Off/Stand-by and Summer/Winter Modes ...................................................................33
3.1.3. On/Off/Stand-by Positions ...............................................................................................................................33
3.1.4. Operation in Winter Mode ............................................................................................................................... 34
3.1.5. Operation in Summer Mode ............................................................................................................................ 34
3.1.6. Shutting off the Combi Boiler ..........................................................................................................................35
3.2. USE WITH ROOM THERMOSTAT (OPTIONAL) ............................................................................................35
3.3. USE OF OUTSIDE TEMPERATURE SENSOR (OPTIONAL) ........................................................................35
3.4. CUSTOMIZING COMBI BOILER FEATURES .................................................................................................. 36
3.5. TROUBLESHOOTING ...........................................................................................................................................37
3.6. RECOMMENDATIONS FOR ECONOMICAL USE OF COMBI BOILER ....................................................44
3.7. ISSUES REQUIRED TO BE TAKEN INTO CONSIDERATION FOR WARRANTY CONDITIONS ........44
3.8. TECHNICAL TABLE ............................................................................................................................................. 46
3.9. PRODUCT FICHE & ERP DATA TABLES .........................................................................................................47
3.10. ENERGY LABEL .................................................................................................................................................. 49