31
warmhaus.com
Transparent Parameters Menu (TSP)
Designation :
All Warmhaus Wallhung Boilers
Object
Type-model(s)
Burner Control Transparent Parameter List
Parameter no.
Parameter
Value Field
MINERWA 25
Default
P01
Hydraulic system
0 – 3
3
0 = Instantaneous
1 = Thermostat storage tank
2 = NTC Storage tank
3 = Heating Only
P02
Gas type
0 – 1
0 = NG
0 = Natural gas
1 = LPG
P03
DHW inlet configuration
0 – 2
1
0 = Flow switch
1 = Flow meter
2 = Flow meter AND W/O DHW Sensor Algorithm
P04
KT coefficient for regulation with EXT probe
4 - 90
30
P05
Anti fast cycles time ( value 1 = 1 minute )
0 - 10 min
3
P06
Maximum CH power
0 % - 100 %
N/A
P07
Ignition heating ramp time (value 1 = 10 seconds)
0 - 80
60
P08
Maximum CH power
P10 - 100 %
80
P09
Maximum DHW power
P10 - 100 %
100
P10
Minimum power
0 % - P09
0
P11
CH Minimum temperature setpoint value ( C° )
20 C° - P12
25
P12
CH Maximum temperature setpoint value ( C° )
P11 - 85 C°
80
P13
DHW maximum temperature setpoint value ( C° )
35 C° - 65 C°
60
P14
Type of calibration
0 - 20
0
0 = Manuel calibration / ma - nu
5 = Auto calibration / Au - To
4.1.2. PARAMETERS