42
warmhaus.com
4.4. INFORMATION MENU ACCESS
Info Menu
Designation:
MinerWa 25 wall-hung boilers
Object
Type-model / Technical data
Mark (s) of conformity
Procedure Info Menu
MinerWa 25 System – IE
granted by Warmhaus R&D
Pos No Operation
Description GB
0
Attention:
This procedure must be applied by authorized persons.
1
Press the RESET and CH (+) button simultaneously.
2
Wait until the approval circle complete on the LCD and release buttons.
3
Now you are in the “Info” menu. Toggle the values by pressing DHW ( + ) OR DHW ( - ) buttons. You can not change
the values displayed in the “info” menu. From this moment by toggle DHW (+) you can check following Informations:
Last 10 Failure ( Error ) codes - Information by reading some real values – Counters Menu
4
From AL 0 to AL9 show last 10 Error code that boiler had previously. Error code shown after the AL code (ie. When
you see AL0 on the screen wait 1-2 sec the error code will show like E06.)
5
INFO MENU=In X value shows following information
In1=SW version
In2=Display of external probe temperature, if connected,°C
In3=Display of CH Flow probe temperature,°C
In4=Display flue probe temperature,°C
In5=Display of DHW probe temperature,°C
In6=Display of CH Return probe temperature,°C
In7=Display of real heating temperature SET,°C
In8=Display of actual power level, %
In9=Display of Flow-meter actual value, Lt / per-minute
In10=Display of water pressure value (on PLUS models ONLY), Bars
In11=Actual Fan Speed, RPMx100