32
10
Disposal of cleaning and servicing substances
Waste spraying media and waste material from cleaning and servicing must be
disposed of in accordance with all applicable local and national regulations.
Warning
Observe the instructions issued by the manufacturers of the spraying and cleaning
material at all times.The improper disposal of waste material endangers the health
of human beings and animals!
11
Technical data
Weight:
245 g/ 0,54 Ib
Connections:
Atomizing Air:
PK 4
Material Inlet:
PK 4
Nozzle sizes available:
0.2 • 0.3 • 0.5 • 0.8 • 1.0 • 1.2 • 1.5 mm ø
Air Caps:
Wide/Flat Air Cap
max. Atomising Air Pressure:
6 bar/ 87 psi
max. Operating temperature:
43°C/ 109,4 °F
Noise Level
(measured at approx.
1 m from the spray gun)
72 dB (A)
Air Consumption:
Input Pressure
Air Consumption
1,0 bar/ 15 psi
46 l / Min
2,0 bar/ 29 psi
78 l / Min
3,0 bar/ 44 psi
119 l / Min
4,0 bar/ 58 psi
156 l / Min
5,0 bar/ 73 psi
189 l / Min
6,0 bar/ 87 psi
219 l / Min
Right to effect technical changes reserved.