26
BXTR6438
0:00 HOURS
ROTOR SPEED
FEED POSITION
NEUTRAL
RPM
0000
01245
01234
SETTINGS
FEED SETTINGS
RESET DEFAULTS
DIAGNOSTICS
SELECT MACHINE
ENTER PASSWORD
Settings screen
Press the soft key button below the icon to access
Settings
. This is the main screen to set up all your
machine parameters. All settings are retained when
the machine is shut down.
The
Settings
screen menu contains:
• Feed Settings – Set the maximum and minimum feed
roller speed settings, feed roller start rpm, minimum
feed roller speed.
• Reset Defaults – Returns all settings to the factory
default values.
• Diagnostics – Provides an overview of operating
parameters; rotor speed, solenoid valve current,
feed roller position. Used for debugging and testing
purposes.
• Select Machine – Chose machine model to set the
default operating parameters for your machine.
• Enter Password – This password protected menu
provides access to factory settings.
Use the Up and Down arrows to cycle through
the menus. The active selection is highlighted.
Press the soft key below
icon to select that menu.
Feed Settings screen
Feed Settings
screen provides access to the four
main P3 PULSE program settings.
The active selection is highlighted. Pressing
advances to the next setting.
Max Feed Speed
is the
first menu accessed.
•
To make adjustments within any menu, press
to
advance to that menu, then use Up and Down
arrows to make any changes.
•
Pressing
saves your new setting and advances to the
next menu to the right. Press
as required to exit back
to
Settings
screen.
01250
FEED SETTINGS
MAX FEED
SPEED
MIN FEED
SPEED
FEED START
SPEED
MIN ROTOR
RPM
0%
0%
0000
0000
Fig. 4 –
Settings Screen
Fig. 5 –
Feed Settings Screen
01258
SETTINGS
FEED SETTINGS
RESET DEFAULTS
DIAGNOSTICS
SELECT MACHINE