ELECTRICAL CONNECTIONS
Things to note about the connections
The device uses 12V direct current voltage. To minimise current losses, make the
power cable as short as possible and avoid jointing. The cross-sectional area of
the cable is dependent on the length of the power cord. See table. The cross-sec-
tional area of the cable must be consistent all the way from the stove to the battery.
The maximum length of the power cord is 10 m.
GB
Installation
Total length of the power cord (m)
Cross-sectional are of the cable (mm
2
)
If a thicker cable is required, make a separate joint in the power cord. See picture 1
on the next page.
Main switch
A main switch (accessory) must be installed on the device’s plus cord. Always cut
the power at the main switch, if the device is going to be left unused for a longer
period of time.
Never use the main switch to cut the power before the cooling phase,
which starts after stove is turned off, is completed.