30014

30012

30011

Figure 11:

Table 1:

- Inclusion of a solenoid valve in the fuel hose near the

tank is necessary if the tank’s fuel level is above the
oven’s or stove’s bottom.

- If the fuel tank is more than 0.5 m above or 1.5 m

below the oven or stove, check the fuel feed and
make any necessary adjustments in accordance
with the separate instructions.

- The fuel hose must always have a fuel filter.
- In the combined unit there is a T-connector for fuel

hoses.  The common fuel hose of the oven and stove
is connected into the branch downwards so the play
can be turned under the oven.

- The fuel hose joints must be fully tightened!

Check the joining surfaces for dirt before
tightening.

Electrical Connection

Important:
- During start-up, the appliance uses approx. 8 amps

of current for 2.5 – 6 minutes.

- A 15 amp fuse must be mounted close to the battery.
- Take the appliance’s power directly from the battery

terminals, not the fuse box or distributing box, to
minimise voltage loss.

- The cables must be protected if there is a risk of

mechanical damage.

- Table 1 shows the minimum diameter of the cables.
- Connect the electric cable’s red lead to the plus (+)

terminal and the black lead to the minus (-) terminal.

- The cables are protected by rubber rings. In the

protection balk down back  there are fixing points
for both oven and stove cables. Care must be taken
that the wires don´t come into contact  with the
exhaust. Turn the play under the oven.

Figure 12: Oven connection.

Connector for the oven control panel

Solenoid valve

Power cable

Fuel hose

 Solenoid valve with 97D oven-stove unit

Installing the Lead-Through

Installation Considerations
- The exhaust pipe should be bent into the shape of a

gooseneck to prevent water from splashing into the
unit.

- The exhaust pipe must be insulated a bendable  metal

pipe that is larger in diameter than the normal
exhaust pipe.

- The Insulation pipe is connected to the fresh air duct

of combination lead-through.

- In a metal-hulled boat it is recommended to insulate

the lead-through to prevent electro-chemical
corrosion.

- There is an separate instruction for lead-throughs.

Connecting the Fuel System to the
Boat’s Main Tank

If solenoid valve must be installed to the fuel system,

it must open when one or both appliances are used.

   97D oven-stove unit has in build a relay pcb. Install

solenoid valve wires to connection C2. Solenoid valve
uses always two wires; these wires are included in
the solenoid valve kit 30012.

l

a

c

i

r

t

c

e

l

e

f

o

h

t

g

n

e

L

)

m

(

e

l

b

a

c

e

h

t

f

o

n

o

i

t

c

e

s

-

s

s

o

r

C

)

²

m

m

(

e

l

b

a

c

4

-

0

4

6

-

4

6

6

r

e

v

o

0

1

Summary of Contents for SafeFlame 96 D

Page 1: ...6 D is 1 5 m long Fuel hoses The maximum length of the fuel hose is 8 m the standard fuel hose is 4 m Considerations on the installation place and on its effect on the installation Figure 2 Wallas Saf...

Page 2: ...ng cleat for the rear pads 355 mm from the front edge of the installation opening 2 Lift the oven into the installation opening so that the rear pads slide into the grooves on the fastening cleat 3 Fi...

Page 3: ...to the minus terminal The cables are protected by rubber rings In the protection balk down back there are fixing points for both oven and stove cables Care must be taken that the wires don t come into...

Page 4: ...rs in the text refer to the numbers in figure 14 1 The recirculation fan heats the oven by cycling air from the heat exchanger to the oven When the power switch is turned to the ON position the oven r...

Page 5: ...the ON position The power switch yellow indicator lights up to indicate that the appliance is turned on A flashing yellow indicator indicates low voltage If the flashing continues for 4 5 minutes or...

Page 6: ...tection beam behind the oven Arrows in figure 15 a 2 Disconnect the electrical wire control cable fuel hose and oven s temperature sensor Circles in figure 15 a Disconnect also the wire of the oven s...

Page 7: ...19 Remove the insidewindow of the shutter Clean the windows and put the insidewindow back to its place Close the screws of the shutter Winter Storage In the spring after winter storage it is important...

Page 8: ...h C e g r a h c d n a n o i t i d n o c r e t e m a i d e h t k c e h C e l b a c r e w o p e h t f o s n o i t c e n n o c e h t d n a t i f o p o r d f o g n i n r a W e g a t l o V n i o L e l b i...

Page 9: ...of foreign origin have been added to the equipment or its structure has been changed without the distributor s or manufacturer s consent 5 Natural wearing faulty handling unsuitable fuel under pressur...

Page 10: ...ad through 3468 The hull or deck lead through 30011 Connection pack to feed fuel directly from the boat s main tank 30012 Solenoid valve to be installed close to the tank if the fuel level is above th...

Reviews: