background image

SafeFlame 96 D / 97 D

6

SERVICE INSTRUCTIONS

Regular service

- Possible crust from the burner should be cleaned in

regular service. If necessary, the bottom carpeting
of the burner and fuel needle should be changed.

- Crust develop around the bottom of the burner from

the aromatic substances found in fuel. The rate at
which this happens depends on the quality of fuel
used and the output of the heater. As a result, the
need for cleaning may vary.

- We recommend the first service after 500 hours of

use. On the basis of the first service, you can then
decide for yourself what would be an adequate
maintenance interval.

- A ‘Ser’ sign appears in the display when 500 hours

have passed. Acknowledge the service indication
by turning the power on while keeping the clock
button depressed, CLS sign on display.

- Instructions for cleaning the burner during the periodic

service are given below.

Cleaning the Oven Burner
1.Open the burner unit protection beam behind the

oven. Arrows in figure 15 a.

2.Disconnect the electrical wire, control cable, fuel

hose and oven’s temperature sensor. Circles in figure
15 a. Disconnect also the wire of the oven’s
circulation fan. The hand in Figure 15 a.

3.Remove the oven’s burner unit by moving the two

safety clamps to the side. Figure 15 b.

4.Remove the glow plug, the burner temperature sensor

and fuel needle by opening the fastener screws and
pulling the parts out of the burner. Figure 16.

5. If the fuel needle is clogged, detach the needle from

the fuel pump and screw in a new needle. The circle
in figure 16 a.

Figure 16:

Figure 15:

A

B

Figure 17:

A

B

6.Open the bottom of the combustion chamber by

removing the two nuts. Pressed against the bottom
is a spring, which keeps the burner cylinder in place.
Figure 17 a. Pull the burner cylinder out of the burner
chamber.

7.Remove the reflector dome from the burner by

pressing the locking tongues in the cylinder wall
with e.g. a screwdriver and tilting the reflector dome.
Figure 17 b.

8.Remove any crust on the base and walls of the burner

by careful scraping. If needed clean burner’s radiator,
too.

Summary of Contents for SafeFlame 96 D

Page 1: ...6 D is 1 5 m long Fuel hoses The maximum length of the fuel hose is 8 m the standard fuel hose is 4 m Considerations on the installation place and on its effect on the installation Figure 2 Wallas Saf...

Page 2: ...ng cleat for the rear pads 355 mm from the front edge of the installation opening 2 Lift the oven into the installation opening so that the rear pads slide into the grooves on the fastening cleat 3 Fi...

Page 3: ...to the minus terminal The cables are protected by rubber rings In the protection balk down back there are fixing points for both oven and stove cables Care must be taken that the wires don t come into...

Page 4: ...rs in the text refer to the numbers in figure 14 1 The recirculation fan heats the oven by cycling air from the heat exchanger to the oven When the power switch is turned to the ON position the oven r...

Page 5: ...the ON position The power switch yellow indicator lights up to indicate that the appliance is turned on A flashing yellow indicator indicates low voltage If the flashing continues for 4 5 minutes or...

Page 6: ...tection beam behind the oven Arrows in figure 15 a 2 Disconnect the electrical wire control cable fuel hose and oven s temperature sensor Circles in figure 15 a Disconnect also the wire of the oven s...

Page 7: ...19 Remove the insidewindow of the shutter Clean the windows and put the insidewindow back to its place Close the screws of the shutter Winter Storage In the spring after winter storage it is important...

Page 8: ...h C e g r a h c d n a n o i t i d n o c r e t e m a i d e h t k c e h C e l b a c r e w o p e h t f o s n o i t c e n n o c e h t d n a t i f o p o r d f o g n i n r a W e g a t l o V n i o L e l b i...

Page 9: ...of foreign origin have been added to the equipment or its structure has been changed without the distributor s or manufacturer s consent 5 Natural wearing faulty handling unsuitable fuel under pressur...

Page 10: ...ad through 3468 The hull or deck lead through 30011 Connection pack to feed fuel directly from the boat s main tank 30012 Solenoid valve to be installed close to the tank if the fuel level is above th...

Reviews: