88DU
Technical information
GB
490070GB
Stove operation
The 88DU is a safe diesel stove with no open
fl
ame. The stove is equipped with
a single burner which burns either diesel oil or light furnace oil. The stove takes
the air needed for the burning process from the boat and discharges the resultant
smoke with a combustion air blower. This means that, when the stove is being
used, the air in the boat circulates and stays fresh and dry. The steam in the
fl
ue
gas does not remain in the boat and increase interior humidity.
The fuel pump in the stove dispenses fuel, and the electronics control the combus-
tion air and the amount of fuel automatically to keep the
fl
ame of the burner clean.
When the stove is switched on, the glow plug in the burner ignites the fuel that has
been pumped into the burner. The glow time is
fi
xed: it begins and ends automati-
cally.
The heat sensor in the stove detects the heat of the
fl
ame and lights the red LED
light to signal that the
fl
ame has been ignited.
The heat which is released as the fuel burns is transferred into the ceramic stove
top. The left side of the stove top is hotter, as the burner is located under it. The
power of the stove can be adjusted steplessly. The control adjusts both sides of the
stove simultaneously.
When the stove is switched off, it cools down automatically. The cooling function
ventilates the burner and discharges the
fl
ue gases generated during the switch-off
outside the boat.
The stove lends itself extremely well to cooking and warming up all kinds of foods.
It has been manufactured entirely from stainless materials.
Fuel
Diesel oil, light furnace oil
12 V DC
0,09 - 0,19 l/h
900 - 1900 W
0.3 A (when ignited ca. 4 min. 8 A)
466 x 316 x 172 mm
ca. 9 kg
2 m (4 m, Intake connection set
3430
)
8 m
100 cm
2
2467
,
3468
and
2460
1012
Kettle holder set
1150
Toasting grill
3430
Intake connection set
Operating voltage
Consumption
Heating power
Power consumption
Measurements
Weight
Max. permissible length of the
fl
ue
gas pipe
Max. permissible length of the fuel
hose
Minimum size of the replace-
ment air opening
Suitable
fl
ue gas lead-throughs
Accessories
Technical information
88DU_GB.indd 4
11.06.2008 10:42:20
- 66 -
Summary of Contents for 88DU
Page 2: ......
Page 191: ...88DU RU 490070RU 5 Wallas Wallas Wallas 191...
Page 193: ...88DU RU 490070RU 2 4 Wallas 86D 3430 75 1 193...
Page 194: ...88DU RU 490070RU 3 5 8 6 7 4 1 4 1 4 7 6 3 8 8 6 7 5 3 5 2 194...
Page 195: ...88DU RU 490070RU S 30 50 9 15 13 14 28 9 13 15 45 14 195...
Page 196: ...88DU RU 490070RU 2 0 4 4 6 6 10 4 6 10 1 12 1 10 1 196...
Page 197: ...88DU RU 490070RU 10 7 1 1 24 1 2 13 12 15 1 24 24 12 12 12 197...
Page 198: ...88DU RU 490070RU 4 8 2 0 5 1 0 5 1 0 5 m 1 m 2 m 198...
Page 200: ...88DU RU 490070RU 367215 367215 1 2 3 4 1 2 3 4 5 2 5 200...
Page 202: ...88DU RU 490070RU 30012 30012 30012 1 2 3 1 1 2 2 3 3 30012 202...
Page 203: ...88DU RU 490070RU 5 C 24 C 40 C 0 C 35 40 20 203...
Page 205: ...88DU RU 490070RU 2467 S 2448 2467 min 150 mm 74 mm max 25 mm 125 mm 2467 50 4 x 6 205...
Page 209: ...RU 88DU 490070RU 2 5 4 5 50 209...
Page 210: ...RU 88DU 490070RU 4 5 210...
Page 211: ...RU 88DU 490070RU 1150 1012 3430 3430 211...
Page 212: ...RU 88DU 490070RU 2 3 4 6 Wallas 212...
Page 213: ...88DU RU 490070RU 1 2 2 13 3 1 3 4 5 2 s 2 s 2 s 2 s 30 s 5 213...
Page 214: ...88DU RU 490070RU Wallas Wallas 500 Wallas Wallas 214...
Page 215: ...88DU RU 490070RU 2 1 3 1 2 5 1 2 3 4 5 215...
Page 216: ...88DU RU 490070RU 10 7 10 7 1 2 3 1 3 4 5 216...
Page 217: ...88DU RU 490070RU 217...
Page 218: ...88DU RU 490070RU 10 7 218...
Page 282: ...282...