29
Fig. 10 AIRLOCK
6.
Airlock:
The system is designed with an
airlock to remove material from
the air flow. It is located under
the grain dryer. The collected
material drops into an airlock
compartment as it turns. As the
rotor turns and a compartment
moves from its up position to its
down position, the material in
the rotor compartment will fall
out.
7.
Airlock Unplugging:
If a large piece of debris is drawn into the
intake, it can get into the airlock, stall it and
have to be removed. To unplug, lock out tag
out master panel and remove obstruction
through the
Rotate airlock by hand after obstruction is
removed to be sure airlock turns freely and has
not been damaged. Repair airlock if damaged
before resuming work.
8.
Lock Out Tag Out Procedure:
It is recommended that the customer institute
a formal lock out tag out procedure for their
workplace. In simple terms, this policy would
require every person that will be servicing,
adjusting, maintaining or unplugging the
system to lock out the master panel and
place a tag n it before working on the unit.
Only the person with the tag can unlock the
master switch to allow it to be turned on. This
prevents unauthorized people from starting
up the system and maintains control by the
serviceman working on the system.