6.
Pulley Alignment:
a. Lay a straight-edge across the face of the
pulley.
Fig. 5.10 PULLEYS
b. If the gap between the pulley and the
straight-edge exceeds 1/16 inch (1.5 mm),
the pulleys must be realigned.
c. Review the types of alignment before
starting.
1. Shafts are not parallel to one another.
2. Shafts are not in correct alignment although
they appear parallel when seen from above.
3. Shafts are parallel and in alignment but
pulleys are not in alignment.
4. Correct installation both shafts and pulleys
are parallel and in alignment.
Fig. 5.11 MISALIGNMENT