e. Install and tighten the drain plugs.
f. Remove fill and level plugs.
g. Add Walinga Blower oil or
equivalent to each reservoir until
the oil is just starting to come out of
the level plug hole.
5.
Changing Oil:
a. Place a collection pan or pail under each drain plug.
b. Remove each drain plug.
c. Flush each case and allow several minutes to
drain.
d. Dispose of the oil in an approved manner.
Do not contaminate the worksite with used oil.
h. Install and tighten the fill and level plugs.
i. Install and secure the belt drive covers.
IMPORTANT
Condensation forms and collects inside the
reservoirs during machine operation. Changing oil
removes this water and prevents it from damaging
the gears and bearings.
Fig. 5.14 BLOWER
6.
Cleaning Breathers:
a. Remove breathers and blow out with an air hose.
b. If dirt has caked up in the breather, soak in good
solvent and then blow out. It may be necessary to
use a probe to loosen the dirt.
c. Install and tighten the breather.
d. Install and secure the belt drive covers.
e. Clean vents in end plates located under the
blower on either side of the drain plug.
SCHEMATIC
Vents
Breathers