IRREGULAR HEARTBEAT DETECTOR

The appearance of the 

 icon indicates 

that a pulse irregularity consistent with an 
irregular heartbeat was detected during 
measurement. Usually this is not a cause 
for concern. However, if the symbol appears 
often, we recommend you seek medical 
advice. Please note that the device does not 
replace a cardiac examination, but serves to 
detect pulse irregularities at an early stage. 
Movement, shaking, or talking during the 
measurement can result in pulse irregularities 
that may cause the appearance of this icon. Therefore, it is of great 
importance to not move or talk during measurement. 
To determine the presence of an irregular heartbeat, the average of 
the heartbeat intervals is calculated with the first 3 normal effective 
heartbeat values. It is important to note that the average is not a strict 
mathematical averaging of all recorded intervals. At least 3 beats 
with 25% or greater difference from the average heartbeat interval will 
generate the 

 icon on the screen.  

Important Information:

This blood pressure monitor is not designed for use by people with 
arrhythmias nor for diagnosing or treating an arrhythmia problem. As a 
safeguard, we recommend that if you have arrhythmias, such as atrial 
or ventricular premature beats and atrial fibrillation or any other special 
conditions, you should check with your physician before using your 
blood pressure monitor.

Irregular Heartbeat Detector

Summary of Contents for WGNBPA-220

Page 1: ...5 Year Limited Warranty El manual en espa ol empieza en la p gina 34 WGNBPA 220 WIC 899709 AUTOMATIC ARM Blood Pressure Monitor...

Page 2: ...lood Pressure Monitor Works 8 USAGE INFORMATION Name Function of Each Part 9 Display Explanations 10 Installing Batteries 12 Date Time Set Procedure 13 Using the UltraSoft Arm Cuff 14 Check with Confi...

Page 3: ...portant Notes Regarding Your Blood Pressure Measurement 24 Care Maintenance Cleaning 25 Potential for Electromagnetic Interference 27 Electromagnetic Compatibility EMC 28 Troubleshooting 30 Specificat...

Page 4: ...ents Follow the instructions in this manual and printed on the arm cuff to ensure the appropriate size cuff is being used For those who have undergone mastectomy surgery especially those who have had...

Page 5: ...his device in a home healthcare environment only Use blood pressure monitor only for its intended use DO NOT wrap the cuff around body parts other than your arm DO NOT touch move or shake the device d...

Page 6: ...common High blood pressure dangerously correlates with cardiovascular disease Therefore blood pressure monitoring is important for identifying those at risk Why Do My Readings Vary Blood pressure is...

Page 7: ...ult your physician Although one can easily find where their own blood pressure readings fall on this table this monitor comes equipped with a Risk Category Index that automatically compares each readi...

Page 8: ...essure With one touch of a button the monitor automatically takes the reading during inflation then deflates delivering a quick comfortable and quiet measurement every time Please note that any muscle...

Page 9: ...Tube and Connector Arm Cuff Other Accessories 4 AAA size 1 5V alkaline batteries included Battery Cover Located on bottom of unit NOTE The MEM button is also used to set the date and time LCD Display...

Page 10: ...10 DISPLAY EXPLANATIONS Date Time Indicator Diastolic Pressure Systolic Pressure Heart Rate Irregular Heartbeat Detector...

Page 11: ...m an excessive gap may occur between the arm and the arm cuff and result in the false detection of excessive body motion Check with ConfidenceTM Appears upon first use and then every 30th use during t...

Page 12: ...o not mix alkaline standard carbon zinc or rechargeable Ni Cad Ni MH etc batteries When installing batteries observe proper polarities Incorrect installation of batteries may cause damage to the unit...

Page 13: ...o confirm the entry The screen will then show a blinking number representing the DAY 3 Change the DAY YEAR HOUR MINUTE as described in Step 2 above using the MEM button to change the numbers and the b...

Page 14: ...ics Consumer Relations at 1 800 466 3342 NOTE If an oversized cuff is used the blood pressure measurement tends to inaccurately run lower than the actual blood pressure If an undersized cuff is used t...

Page 15: ...it 4 Remove tight fitting clothing from your upper left arm so that the cuff can be wrapped around your exposed arm NOTE It is recommended to wrap the cuff on a bare arm or over thin clothing to ensu...

Page 16: ...over middle of arm 7 Pull the end of the cuff so that it tightens evenly around your arm Press the hook and loop material together to secure ensuring the cuff does not slip during measurement Allow r...

Page 17: ...not possible to fit the cuff on your left arm it can also be placed on your right arm However all measurements should be made using the same arm To use on the right arm you must position the artery sy...

Page 18: ...tton for 3 seconds On first use then on every 30th use the cuff will partially inflate and then deflate The monitor will display OK confirming the monitor is working properly NOTE If the MEM and START...

Page 19: ...Wait 1 hour after exercising bathing eating drinking beverages with alcohol or caffeine or smoking to measure blood pressure Sit quietly and rest for 15 minutes Stress raises blood pressure Avoid taki...

Page 20: ...all symbols disappear the display will show 00 The monitor is ready to measure and will automatically inflate the cuff to start measurement 3 When the measurement is completed the cuff will deflate en...

Page 21: ...and your noninvasive blood pressure readings as it relates to the AHA 2017 information They are not a substitute for a medical examination by your physician It is important for you to consult with you...

Page 22: ...ent To determine the presence of an irregular heartbeat the average of the heartbeat intervals is calculated with the first 3 normal effective heartbeat values It is important to note that the average...

Page 23: ...e accurate if the icon is displayed If you have purchased and are using the XL cuff for arm sizes 17 22 a gap between the cuff and the arm could cause this icon to display Adjust cuff as directed and...

Page 24: ...the same arm for consistency Users should wait a minimum of 5 minutes before taking additional measurements More time may be necessary depending upon your physiology The measurement results that user...

Page 25: ...e to room temperature before use This blood pressure monitor is not field serviceable You should not use any tool to open the device nor should you attempt to adjust anything inside the device If you...

Page 26: ...ccidental strangulation keep this product away from children Do not drape tube around neck This monitor may not meet its performance specifications if stored or used outside of these temperature and h...

Page 27: ...nt has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inte...

Page 28: ...lectromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 8 kV contact discharge 15 kV air discharge 8 kV contact discharge 15 kV air discharge In the case of air discharge testing...

Page 29: ...1000 4 3 10 V m at 80 2700 MHz AM Modulation and 9 28V m at 385 6000MHz Pulse Mode and other Modulation The system shall be tested as specified in IEC60601 1 2 Table 9 for proximity fields from RF wir...

Page 30: ...d the arm cuff Ensure the cuff is wrapped correctly Please consult your healthcare professional if you have questions on how to properly wear the arm cuff EP error symbol shown on display System error...

Page 31: ...ute after last button operation Battery Life Approx 300 Measurements Product Life 5 Years 4 times per day Operation Environment Temperature 41 F 104 F 5 C 40 C Humidity 15 93 RH Atmospheric pressure 7...

Page 32: ...degradation of the performance of this equipment could result Waste of electrical and electronic equipment WEEE Serial number YYMMXXXX Ingress Protection Rating First characteristic numeral Degree of...

Page 33: ...nce transportation damage theft neglect vandalism or environmental conditions loss of use during the period the product is at a repair facility or otherwise awaiting parts or repair or any other condi...

Page 34: ...Garant a limitada de 5 a os WGNBPA 220 WIC 899709 BRAZO AUTOM TICO Monitor de Presi n Arterial...

Page 35: ...de presi n arterial 41 INFORMACI N DE USO Nombre Funci n de cada parte 42 Explicaciones de la pantalla 43 Colocaci n de bater as 45 Procedimiento para ajuste de fecha y hora 46 C mo usar el brazalete...

Page 36: ...57 Notas importantes respecto a su medici n de la presi n arterial 57 Cuidados mantenimiento y limpieza 58 Potencial de interferencia electromagn tica 60 Compatibilidad electromagn tica EMC 61 Soluci...

Page 37: ...sas Siga las instrucciones en este manual e impresas en el brazalete para asegurarse de que est utilizando el tama o apropiado Para quienes hayan tenido una cirug a de mastectom a especialmente si se...

Page 38: ...biente de cuidados m dicos en el hogar Use el monitor de presi n arterial solamente para su uso previsto NO enrolle el brazalete alrededor de otras partes del cuerpo que no sean el brazo NO toque muev...

Page 39: ...i n est correlacionada peligrosamente con enfermedad cardiovascular Por lo tanto el monitoreo de la presi n arterial es importante para identificar aquellas personas en riesgo Por qu var an mis medici...

Page 40: ...ar a su m dico Aunque uno puede determinar f cilmente en qu rango de la tabla est n las mediciones propias este monitor viene equipado con un indicador de categor a de riesgo que compara autom ticamen...

Page 41: ...mente realiza la medici n durante el inflado despu s se desinfla y proporciona una medici n r pida c moda y silenciosa en cada ocasi n Tome en cuenta que cualquier movimiento muscular durante el infla...

Page 42: ...zalete para brazo Otros accesorios 4 bater as alcalinas AAA de 1 5 V incluidas Cubierta de bater as ubicada en la base de la unidad NOTA El bot n MEM tambi n se usa para ajustar la fecha y la hora Pan...

Page 43: ...43 EXPLICACIONES DE LA PANTALLA Indicador de Fecha Hora Presi n Diast lica Presi n Sist lica Frecuencia Card aca Detector de Latidos Irregulares...

Page 44: ...haber una brecha excesiva entre el brazo y el brazalete para brazo lo cual podr a resultar en la detecci n falsa de movimiento corporal excesivo Check with ConfidenceTM Aparece cuando se usa por prim...

Page 45: ...V No mezcle bater as alcalinas est ndar carbono zinc o recargables Ni Cad Ni Mh etc Al instalar las bater as observe que la polaridad sea correcta Una instalaci n incorrecta de las bater as puede caus...

Page 46: ...n para confirmar la opci n La pantalla mostrar un n mero parpadeante que muestra el D A 3 Cambie el D A A O HORA y MINUTO como se describe en el paso 2 anterior usando el bot n MEM para cambiar los n...

Page 47: ...n Relaciones con el Cliente de HoMedics al 1 800 466 3342 para comprarlo A R R O W M U S T FA LL W IT H IN B LU E B A N D ARROW MUST FALL WITHIN BLUE BAND Center tube over middle of arm Position cuff...

Page 48: ...etire ropa que le ajuste firmemente de su brazo de tal forma que el brazalete puede enrollarse alrededor de su brazo expuesto NOTA Se recomienda ajustar el brazalete sobre el brazo desnudo o sobre rop...

Page 49: ...io del brazo 3 Jale el extremo del brazalete para ajuste uniformemente alrededor de su brazo Presione los materiales de velcro para asegurarlos garantizando que el brazalete no se resbale durante la m...

Page 50: ...su brazo izquierdo tambi n puede colocarse en su brazo derecho Sin embargo todas las mediciones deber n hacerse usando el mismo brazo Para usar el brazalete en el brazo derecho debe colocar el s mbol...

Page 51: ...OP durante 3 segundos Durante el primer uso y despu s de cada 30 veces que se use el brazalete se inflar parcialmente y despu s se desinflar El monitor mostrar OK confirmando que el monitor est funcio...

Page 52: ...e hacer ejercicio ba arse comer ingerir bebidas alcoh licas o con cafe na o fumar para medir la presi n arterial Si ntese tranquilamente y descanse por 15 minutos Es estr s eleva la presi n arterial E...

Page 53: ...desaparezcan todos los s mbolos la pantalla mostrar 00 El monitor est listo para medir e inflar autom ticamente el brazalete para comenzar la medici n 3 Cuando la medici n haya concluido el brazalete...

Page 54: ...por comodidad para ayudarle a entender su medici n de presi n arterial no invasiva y c mo se interpreta de acuerdo con la informaci n de la AHA de 2017 No son un sustituto de una revisi n de su m dico...

Page 55: ...nte la medici n Para determinar la presencia de un latido irregular el promedio de los intervalos de latidos se calcula con los primeros 3 valores normales efectivos de latidos Es importante notar que...

Page 56: ...cono Si adquiri y est usando el brazalete XL para brazos de entre 43 cm 56 cm 17 22 una brecha entre el brazalete y el brazo podr a hacer que aparezca este icono Ajuste el brazalete como se indica y r...

Page 57: ...azo por consistencia Los usuarios deber n esperar un m nimo de 5 minutos antes de tomar mediciones adicionales Puede que necesite m s tiempo dependiendo de su fisiolog a Los resultados de medici n que...

Page 58: ...ta que se aclimate a temperatura ambiente antes de usarse Este monitor de presi n arterial no es apto para su servicio en campo No deber usar ninguna herramienta para abrir el dispositivo ni deber int...

Page 59: ...evitar estrangulaci n accidental mantenga este producto lejos de los ni os No coloque el tubo alrededor del cuello Este monitor podr a no cumplir con sus especificaciones de desempe o si se guarda o u...

Page 60: ...del usuario para operar el equipo Este equipo ha sido probado y se encontr que cumple con los l mites de un dispositivo digital Clase B de conformidad con la Parte 15 de las Reglas de FCC Estos l mit...

Page 61: ...prueba IEC 60601 Nivel de cumplimiento Ambiente electromagn tico orientaci n Descarga electrost tica ESD IEC 61000 4 2 8 kV descarga al contacto 15 kV descarga en aire 8 kV descarga al contacto 15 kV...

Page 62: ...EC 61000 4 3 10 V m a 80 2700 MHz Modulaci n de AM y 9 28 V m a 385 6000 MHz modo de pulso y otra modulaci n El sistema debe ser probado como se especifica en IEC60601 1 2 tabla 9 para campos de proxi...

Page 63: ...o Consulte a su profesional del cuidado de la salud si tiene preguntas sobre c mo usar correctamente el brazalete para brazo El s mbolo de error EP mostrado en la pantalla Error del sistema Apague el...

Page 64: ...operaci n de alg n bot n Vida de la bater a Aprox 300 mediciones Vida del producto 5 a os si se usa 4 veces al d a Ambiente de operaci n Temperatura 41 F 104 F 5 C 40 C Humedad 15 93 HR Presi n atmosf...

Page 65: ...ispositivo De lo contrario podr a resultar una degradaci n en el desempe o de este equipo C mo desechar equipos el ctricos y electr nicos WEEE N mero de serie YYMMXXXX Primer numeral caracter stico Gr...

Page 66: ...porcionar el mantenimiento recomendado por el fabricante da o al transportarlo robo negligencia vandalismo o condiciones ambientales p rdida del uso durante el per odo en que el producto se encuentre...

Reviews: