356.805.003
10
Date: 2019-04-04
AC power
WARNING
! Read “Safety Information” on page
2 before connecting the product to AC mains
power.
WARNING! For protection from electric shock, do not power the track when not in use or when
servicing.
Power cables and power plug
The track system requires a power input cable with a Neutrik powerCON TRUE1 NAC3FX-W(-TOP)
cable connector for AC mains power input, and also the TrackRunner Upright requires a NAC3MX-
W(-TOP) cable connector for AC output to a powered fixture. The cable must rated 20A minimum,
have three conductors 1,5mm2 (AWG 16) minimum conductor size and an outer cable diameter
of 6-16mm (0.24-0.47 inch). Cables must be heat resistant to 90°C (194°F) minimum. In the EU the
cables must be <HAR> approved or equivalent and in the USA minimum hard usage type SJT or
equivalent.
If you install a power plug on the power cable, install a grounding-type (earthed) plug that is rated
20 A for USA and 16A for Europe.
Follow the plug manufacturer’s instructions. Table 1 shows
standard wire color-coding schemes and some possible pin identification schemes; if pins are not
clearly identified, or if you have any doubts about proper installation, consult a qualified
electrician.
Table 1 - Colour guide
Wire Colour
Conductor
Symbol
Screw (US)
Brown
Live
L
Yellow or brass
Blue
Neutral
N
Silver
Yellow/green
Ground (earth)
or
Green
Installing a power input or output connector on a power cable
To install a Neutrik powerCON TRUE1 NAC3FX-W(-TOP)/NAC3MX-W(-TOP) input/output
connector on a power cable, follow the original Neutrik instructions in Appendix 2
Connectors on page 24.