8.3.5
Setting Parameters
Table 47: Adjustable Parameters
Parameter name
Value range
Module parameters
Analog value data
format
Format Siemens S7 with fixed substitute values
Format Siemens S7 with parameterizable substitute
values(
RIOforPA
Sampling frequency
100 Hz
60 Hz
50 Hz*
10 Hz
Acknowledgement mode
Module-internal
Module-external*
PROFIsafe V2.4
passivation mode
Channel granularity
Module-wide*
Channel pair parameters
Sensor evaluation
Single-channel*
Two-channel
Discrepancy time
5
… 65535 ms (100 ms*)
Unit value
Min*
Max
Tolerance window
Relative
Absolute
Ab relative*
Relative tolerance
±0.2
… ±20 % (2 %*)
Absolute tolerance
±0.2
… ±20 % (2 %*)