Web-based Management (WBM) 111
750-375 PROFINET IO advanced Fieldbus Coupler
Manual
Version 1.1.0
9.4
TCP/IP
The WBM page "TCP / IP" contains information about the currently existing IPv4
settings.
Figure 52: WBM page „TCP/IP“
Table 52: Description of the parameters of the WBM page "TCP/IP"
Active used TCP/IP Configuration
IP address
Displays the current IP address of the fieldbus coupler.
Subnet mask
Displays the current subnet mask of the fieldbus coupler.
Gateway
Displays the current gateway address of the fieldbus coupler.
Permanent stored TCP/IP Configuration
IP address
Displays the IP address of the fieldbus coupler stored in non-
volatile memory.
Subnet mask
Displays the subnet mask of the fieldbus coupler stored in non-
volatile memory.
Gateway
Displays the gateway address of the fieldbus coupler stored in
non-volatile memory.
9.5
Diagnostics
In the event of an error, the WBM page "Diagnostics" displays diagnostic
messages in the form of a log.
The
[Refresh]
button can be used to refresh the list of diagnostic information.
For evaluation, the item number of the module affected by the error, slot, error
code and respective error description are displayed.
The user is referred to the device manual if there is no detailed error description
for a diagnostic on the fieldbus coupler.