background image

WAFER  GSM-CTL  REMOTE  CONTROL  UNIT 

http://www.waferstar.com 

Acknowledge:

 

CSQ IS 26

 

 

#PWD123456#STATUS? 

Acknowledge:

 

ACM=ON,REPLY=ON,RELAY=MODE0,GOT=3S, CSQ=20,OUT=0000000

 

 

Customized Text Command to control the OUTPUT: 

#PWD123456#OUT1-ON-TEXT:XXXX 
#PWD123456#OUT1-OFF-TEXT:XXXX 
#PWD123456#OUT1-ON-REPLY-TEXT:XXXX 
#PWD123456#OUT1-OFF-REPLY-TEXT:XXXX 
 
#PWD123456#OUT2-ON-TEXT:XXXX 
#PWD123456#OUT2-OFF-TEXT:XXXX 
#PWD123456#OUT2-ON-REPLY-TEXT:XXXX 
#PWD123456#OUT2-OFF-REPLY-TEXT:XXXX 
 
#PWD123456#RLY1-TEXT:XXXX 
#PWD123456#RLY1-REPLY-TEXT:XXXX 
#PWD123456#RLY2-TEXT:XXXX 
#PWD123456#RLY2-REPLY-TEXT:XXXX 
 
Text Command QUERY: 

#PWD123456#OUT-TEXT?          (only for PC command) 

REPLY: 
OUT1-ON:WSD1ON 
OUT1-OFFWSD1OFF 
OUT2-ON:WSD2ON 
OUT2-OFFWSD2OFF 
 

#PWD123456#OUT-REPLY-TEXT?          (only for PC command)

 

OUT1-ON-REPLY-TEXT:WSD1ON OK 
OUT1-OFF-REPLY-TEXT:WSD1OFF OK 
OUT2-ON-REPLY-TEXT:WSD2ON OK 
OUT2-OFF-REPLY-TEXT:WSD2OFF OK 

 
PWD123456#RLY-TEXT?          (only for PC command) 

RLY1-TEXT:WSDRLY1 
RLY1-REPLY-TEXT:WSDRLY1 OK 
RLY2-TEXT:WSDRLY2 
RLY2-REPLY-TEXT:WSDRLY2 OK 
 

Data Log Check (Only for PC Connnecting) 

With this command,we can check the inside config and control Log information 

#PWD123456#LOG=ALL? 

Summary of Contents for GSM-CTL

Page 1: ...WAFER GSM CTL REMOTE CONTROL UNIT http www waferstar com GSM CTL MANUAL V5 0 From 2015 SHANGHAI WAFER MICROELECTRONICS CO LTD...

Page 2: ...phones calling and SMS Relay operates almost every electric applicance Remote password operation and also password change Opetional relay working mode One relay output with the calling mode and other...

Page 3: ...ble the PIN request usually there is a security menu that enables you to do so WAFER GSM CTL PROGRAMMING You can program the GSM CTL with SMS commands using your phone It is safe to do so because in a...

Page 4: ...output delay time MODE Relay mode CSQ Check Signal Quality STATUS Check status Once you issue a command with an SMS you will receive a confirmation SMS with OK if everything is correct or Err if there...

Page 5: ...we advise you to keep a list written somewhere to know which numbers are in and in which position To add a number the syntax of the command is the following PWD123456 WHL01 61143815 Acknowledge would...

Page 6: ...ndard time is 0 3 seconds 300 ms You can change it with the GOT command The syntax of the command is the following PWD123456 GOT500 PC PHONE Only for NO 1 Relay Acknowledge DELAY TIME SET TO 0500MS Wi...

Page 7: ...o 65 000 seconds and receive confirmation SMS text alerts when the Relays switch on and off To activate relay 1 for 60 seconds you would send the following SMS text message to the unit PWD123456 RLY2...

Page 8: ...123456 RLY1 TEXT XXXX PWD123456 RLY1 REPLY TEXT XXXX PWD123456 RLY2 TEXT XXXX PWD123456 RLY2 REPLY TEXT XXXX Text Command QUERY PWD123456 OUT TEXT only for PC command REPLY OUT1 ON WSD1ON OUT1 OFFWSD1...

Page 9: ...501071937 8613564121668 WSDRLY6 6 LOGS020 201501071937 8613564121668 RLY3 8 Normally don t need to use and test the instruction Program software Please download from the product link http www wafersta...

Page 10: ...ing slowly try to call the SIM card the calling status would be in busy MCU LED D4 is not flash slowly MCU is not working properly Check the system power No Relay working tone can be heard when phone...

Page 11: ...or 230VAC 30A Warning GSM CTL device is only working as a high power switch don t power the LOAD directly This brochure provides an overview of the products and services of WEIFU GSM Modules For furt...

Page 12: ...waferstar com Also accessible via our online skype service wafer service Copyright 2008 WEFU GSM V2015New V20111107 Trouble shooting V20111126 Relay connection example V20150101 Customized command sup...