WAFER GSM-CTL REMOTE CONTROL UNIT
http://www.waferstar.com
Troubleshooting
No LED is on after power up
·
Check the power supply.
·
Check the wires is connected well.
GSM
LED D6
is not flash slowly
(GSM LED normally flash quickly when power off and when it connected to GSM net ,then
would flash around two seconds per time).
·
Check your ordered device if that is the proper GSM BAND to your country.
(Some country is QUAD BAND , some others is DUAL BAND, please check wafer website:
http://www.waferstar.com/en/gsm-frequencies-list.html
·
Check the SIM card is properly inserted.
·
Check the PIN.(Normally don’t need to check, if SIM card can work with your mobile phone.)
·
Check the antenna connection is fitted well.
·
GSM Signal is not good and cann’t register to GSM,try to move to another place to test.
·
If still cann’t registered to the GSM net, try to contact wafer to get the technical support
·
When LED D6 is flashing slowly,try to call the SIM card,the calling status would be in busy.
MCU
LED D4
is not flash slowly
·
MCU is not working properly,Check the system power
No Relay working tone can be heard when phone calling the device
·
Check if your Control number is already setup into the device.
·
GSM-CTL is not initialized properly upon start (approx. 10s after power up).
·
If the GOT timer is setup to a very short timer ( normally should be more than 500ms )
GSM-CTL does not communicate with PC
·
Check the serial cable connection.
·
Check the COM number setting on PC.
·
Check if you select the “ New Line ” selection box
·
Check if you input the right instruction line and that should be all use the Capital word,
·
Check the COM parameters (9600 bps, 8N1).
·
An incoming call is ringing on GSM-CTL
·
An incoming SMS message is on processing by GSM-CTL
Relay connection example to Output Driver
The relay control outputs are suitable to control different household and other devices as are
air-conditioning and heating,connected directly or through external relay modules.
The relay has NO and NC contacts,normally,we only need to use the NO and COM contacts.