Maintenance
Chassis/safety devices
BA RD24_RD27 en 04
131
4.01.03
Testing the EMERGENCY STOP function
1
2
2
3
Checking function with machine at standstill (daily)
Engage drive lever [2] in the 0-position.
Start the diesel engine.
Press the parking brake [3] switch.
Press EMERGENCY STOP [1] when engine at standstill.
The machine:
a
switches off the working functions.
a
Shuts down the diesel engine.
Checking function during machine operation (annually)
Perform the functional test while the diesel engine is running.
Press EMERGENCY STOP [1] with low speed 0.5 km/h (0.3 mph).
The machine:
a
Stops immediately.
a
Shuts down the diesel engine.
N
O
T
E
If the machine reacts other than as described above or if the
EMERGENCY STOP does not work, it must be tested and
repaired without delay. The machine must not be used until this
has been done. Request assistance from customer services!