![Wacker Neuson LTV6K Operator'S Manual Download Page 95](http://html1.mh-extra.com/html/wacker-neuson/ltv6k/ltv6k_operators-manual_866644095.webp)
wc_tx004456gb_FM10.fm
95
LTV
Troubleshooting
10 Troubleshooting
WARNING
HIGH VOLTAGE! This unit uses high voltage circuits capable of causing serious
injury or death.
►
Only a qualified electrician should troubleshoot or repair electrical problems
occurring in this equipment.
Problem
Cause
Remedy
Engine doesn’t start
Battery discharged
Charge battery.
Battery connections corroded
Clean battery connections.
Blown fuse
Replace fuse.
Faulty starter
Replace starter.
Engine tries to start
but stops
No fuel
Fill tank with fuel.
Bleed fuel lines.
Clogged fuel filter
Replace fuel filter.
Fuel circuit failure
Check fuel lines.
No generator output
Main circuit breaker open
Close main circuit breaker.
Voltage regulator malfunction
Call Wacker Neuson for service.
Low oil pressure
Low oil level
Fill engine sump with oil.
Clogged oil filter
Replace oil filter.
Oil pump failure
Call Wacker Neuson for service.
High coolant
temperature
Electrical overload
Reduce load.
Low coolant level
Fill with coolant.
Low oil level
Fill sump with oil.
Clogged oil filter
Replace oil filter.
Engine emits black
smoke
Clogged air filter
Clean/replace air filter cartridges.
Electrical overload
Reduce load.
High oil level
Remove excess oil.
Fuel circuit failure
Call Wacker Neuson for service.