BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm
8-39
Malfunctions 8
Displays
There are 2 LED indicator lights in total located under the operator seat on
the front side of the StVZO module. The indicator lights act as a minimal
diagnosis.
Burned out or missing fuses are indicated by means of flash codes via the
diagnosis indicator for fuses
5H18
.
The flash code is composed as follows: the LED is repeatedly switched
briefly on (approx. 0.2 sec) and off (ca. 0.4 sec). Lastly, a longer pause
follows (approx. 2 sec), indicating the end of the start of the flash code.
The number of times the LED is repeatedly switched off
(e.g. 4 times consecutively off = flash code 4).
A
B
Designation LED
Function
5H18
Diagnosis indicator fuse box
A
5H19
Indicator display control
B
Fig. 269
C
B
Fuse box (C)
Flash code LED 5H18 (A)
Defective fuse
2
4F6.1
3
5F5.3
4
5F5.1
5
4F6.2
6
4F5.1
7
4F5.2
8
5F5
9
5F4.1
10
5F4
Summary of Contents for KRAMER 5055e
Page 12: ...1 6 BA 357 00 3 0 35700_01_Vorwort fm 1 Preface Notes...
Page 36: ...2 24 BA 357 00 3 0 Sicherheit_E fm 2 Safety Notes...
Page 98: ...4 26 BA 357 00 3 0 35700_04_Inbetriebnahme_01 fm 4 Putting into operation...
Page 252: ...6 12 BA 357 00 3 0 35700_06_Transport fm 6 Transport Notes...
Page 264: ...7 12 BA 357 00 3 0 35700_07_Wartung fm 7 Maintenance Maintenance label Affixed on the cabin...
Page 340: ...7 88 BA 357 00 3 0 35700_07_Wartung fm 7 Maintenance Notes...
Page 382: ...8 42 BA 357 00 3 0 35700_08_Betriebsst rung fm 8 Malfunctions...
Page 408: ...9 26 BA 357 00 3 0 35700_09_Technische_Daten fm 9 Technical data...
Page 416: ...S 8 BA 357 00 3 0 BA_35700_V3_enSIX fm Index...
Page 417: ...BA 357 00 3 0 BA_35700_V3_enSIX fm S 9 Index...
Page 418: ...S 10 BA 357 00 3 0 BA_35700_V3_enSIX fm Index...