![background image](http://html1.mh-extra.com/html/wacker-neuson/kramer-5055e/kramer-5055e_operators-manual_4515366368.webp)
8-28
BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm
8 Malfunctions
3rd control circuit
Error code FMI
Warning
light
Error description
Remedy
517040
2
Red
B041 – Potentiometer rocker switch (joystick):
Signal is faulty or irregular
– 3rd control circuit and quickhitch unlocking
mechanism without function
Critical error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
3
Yellow
B041 – Potentiometer rocker switch (joystick):
Signal range exceeded or short circuit to positive
supply voltage
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected by
an authorized service
center.
4
Yellow
B041 – Potentiometer switch (joystick):
Signal range fallen below or short circuit to
positive vehicle ground / sensor ground
28
Yellow
B041 – Potentiometer switch (joystick):
Open control circuit or short circuit to positive
supply voltage
517122
3
Yellow
D002 – Potentiometer rocker switch (joystick):
Signal range exceeded or short circuit to positive
supply voltage
4
Yellow
D002 – Potentiometer switch (joystick):
Signal range fallen below or short circuit to
positive vehicle ground / sensor ground
28
Yellow
D002 – Potentiometer switch (joystick):
Open control circuit or short circuit to positive
supply voltage
518981
3
Yellow
S033 – Switch continuous operation:
Signal range exceeded or short circuit to positive
supply voltage
– Continuous functioning of 3rd control circuit
without function
26
Yellow
S033 – Switch continuous operation:
Signal outside of the valid range
– Continuous functioning of 3rd control circuit
without function
27
Yellow
S033 – Switch continuous operation:
Open circuit or short circuit to ground
– Continuous functioning of 3rd control circuit
without function
519919
3
R019-Potentiometer:
signal range exceeded or short circuit to positive
supply voltage
27
R019-Potentiometer:
open circuit or short circuit to ground
Summary of Contents for KRAMER 5055e
Page 12: ...1 6 BA 357 00 3 0 35700_01_Vorwort fm 1 Preface Notes...
Page 36: ...2 24 BA 357 00 3 0 Sicherheit_E fm 2 Safety Notes...
Page 98: ...4 26 BA 357 00 3 0 35700_04_Inbetriebnahme_01 fm 4 Putting into operation...
Page 252: ...6 12 BA 357 00 3 0 35700_06_Transport fm 6 Transport Notes...
Page 264: ...7 12 BA 357 00 3 0 35700_07_Wartung fm 7 Maintenance Maintenance label Affixed on the cabin...
Page 340: ...7 88 BA 357 00 3 0 35700_07_Wartung fm 7 Maintenance Notes...
Page 382: ...8 42 BA 357 00 3 0 35700_08_Betriebsst rung fm 8 Malfunctions...
Page 408: ...9 26 BA 357 00 3 0 35700_09_Technische_Daten fm 9 Technical data...
Page 416: ...S 8 BA 357 00 3 0 BA_35700_V3_enSIX fm Index...
Page 417: ...BA 357 00 3 0 BA_35700_V3_enSIX fm S 9 Index...
Page 418: ...S 10 BA 357 00 3 0 BA_35700_V3_enSIX fm Index...