BA 357-00 * 3.0 * 35700_08_Betriebsstörung.fm
8-23
Malfunctions 8
Differential lock
Error code FMI
Warning
light
Error description
Remedy
518972
3
Yellow
S025 – Push button (joystick):
Signal range exceeded or short circuit to positive
supply voltage
– Differential lock without function
Error
1. Turn off the machine and
then turn it on again.
2. If the error occurs again:
have the error corrected
by an authorized service
center.
27
Yellow
S025 – Push button (joystick):
Open circuit or short circuit to ground
–Differential lock without function
28
Yellow
S025 – Button (joystick):
Open control circuit or short circuit to positive
supply voltage.
– Differential lock without function
519357
5
Yellow
Y009 – Magnetic valve:
Power too low or open wiring
– Differential lock without function
6
Yellow
Y009 – Magnetic valve quickhitch lock:
Power too high or short circuit to vehicle ground
– Differential lock without function
Summary of Contents for KRAMER 5055e
Page 12: ...1 6 BA 357 00 3 0 35700_01_Vorwort fm 1 Preface Notes...
Page 36: ...2 24 BA 357 00 3 0 Sicherheit_E fm 2 Safety Notes...
Page 98: ...4 26 BA 357 00 3 0 35700_04_Inbetriebnahme_01 fm 4 Putting into operation...
Page 252: ...6 12 BA 357 00 3 0 35700_06_Transport fm 6 Transport Notes...
Page 264: ...7 12 BA 357 00 3 0 35700_07_Wartung fm 7 Maintenance Maintenance label Affixed on the cabin...
Page 340: ...7 88 BA 357 00 3 0 35700_07_Wartung fm 7 Maintenance Notes...
Page 382: ...8 42 BA 357 00 3 0 35700_08_Betriebsst rung fm 8 Malfunctions...
Page 408: ...9 26 BA 357 00 3 0 35700_09_Technische_Daten fm 9 Technical data...
Page 416: ...S 8 BA 357 00 3 0 BA_35700_V3_enSIX fm Index...
Page 417: ...BA 357 00 3 0 BA_35700_V3_enSIX fm S 9 Index...
Page 418: ...S 10 BA 357 00 3 0 BA_35700_V3_enSIX fm Index...