7-40
BA EZ17 en* 1.1 * ez17w710.fm
7 Maintenance
NOTICE
Damage to hydraulic system due to dirty hydraulic oil.
►
Always add hydraulic oil using the filling screen.
►
If the hydraulic oil in the sight glass is cloudy, this indicates that water
or air has penetrated the hydraulic system. Contact a Wacker Neuson
service center.
►
Contact a Wacker Neuson service center if the filter of the hydraulic
system is dirty.
Checking the hydraulic oil level
1. Park the vehicle on firm, level, and horizontal ground.
2. Position the boom straight ahead at the center of the machine (see
figure).
3. Lower the boom and the stabilizer blade to the ground.
4. Stop the engine.
5. Operate the control lever repeatedly to release the pressure in the
hydraulic system.
6. Remove the starting key and carry it with you.
7. The inspection glass
A
is located to the right in the vehicle.
8. Check the oil level on sight glass
A
.
➥
The oil level must be at the
MAX
mark after the machine reaches its
operating temperature.
➥
Add hydraulic oil if the oil level is below this mark.
Adding hydraulic oil
1. Press tank ventilation
B
to release the pressure.
Possible designs:
• Up to serial number WNCE1301PPAL00518: circuit breaker
• From serial number WNCE1301KPAL00519: circuit breaker with
cover
F
Fig. 226
Fig. 227
A
MAX
Fig. 228
B
F
Summary of Contents for E13-01
Page 6: ...EG 2 BA EZ17 en 1 1 ez17konf fm Declaration of conformity Notes...
Page 36: ...2 22 BA EZ17 en 1 1 Safety_01_0 fm 2 Safety Notes...
Page 45: ...BA EZ17 en 1 1 ez17e300 fm 3 9 Introduction 3 Warning labels...
Page 50: ...3 14 BA EZ17 en 1 1 ez17e300 fm 3 Introduction Labels...
Page 90: ...4 36 BA EZ17 en 1 1 ez17i400 fm 4 Putting into operation Notes...
Page 158: ...5 68 BA EZ17 en 1 1 ez17b510 fm 5 Operation Notes...
Page 216: ...7 50 BA EZ17 en 1 1 ez17w710 fm 7 Maintenance Notes...
Page 220: ...8 4 BA EZ17 en 1 1 ez17b800 fm 8 Malfunctions Notes...
Page 244: ...9 24 BA EZ17 en 1 1 ez17t900 fm 9 Technical data Dimensions Fig 243...
Page 246: ...9 26 BA EZ17 en 1 1 ez17t900 fm 9 Technical data Notes...