![Wacker Neuson DPU 5545He Operator'S Manual Download Page 39](http://html1.mh-extra.com/html/wacker-neuson/dpu-5545he/dpu-5545he_operators-manual_3277957039.webp)
Maintenance
T00997GB.fm
39
5.5
Exciter
5.5.1
Check oil level:
1. Position vibration plate horizontally.
2. Open filler bore (30).
3. The oil level must reach the start of the thread of the filler bore.
4. If necessary, pour in Fuchs Titan Unic 10W40 MC through filler bore
(use funnel 0,75 l).
5. Close filler bore. (Tightening torque 100 Nm)
5.5.2
Changing the oil:
1. Open filler bore (30).
2. Tilt vibration plate and keep it tilted until the oil has run out.
3. Place vibration plate in horizontal position.
4. Pour in 0,75 l Fuchs Titan Unic 10W40 MC through the filler bore.
5. Close filler bore. (Tightening torque 100 Nm)
Do not pour in too much oil!
Take notice:
Please pay attention to the corresponding environmental
laws when disposing of used engine oil. We recommend you carry the
oil in a container to a central collecting point for used oils. Do not pour
used engine oil into the garbage nor into the sewer system, waste
pipes or even on the ground.
Oil