![Wacker Neuson DPU 5545He Operator'S Manual Download Page 36](http://html1.mh-extra.com/html/wacker-neuson/dpu-5545he/dpu-5545he_operators-manual_3277957036.webp)
Maintenance
T00997GB.fm
36
5.2
Engine oil
5.2.1
Check oil level:
∗
Check oil level with oil dipstick (21).
∗
.If the oil level is too low, top up with Fuchs Titan Unic 10W40 MC
though the filler neck (19).
5.2.2
Changing the oil:
1. Let engine warm up.
2. Loosen oil drain screw.
3. Loosen fastening screws and place bracket over used oil container.
4. Remove oil drain screw and pour oil into container.
5. Screw oil drain screw back in and refasten bracket.
6. Pour in 1,0 l of oil through the filler neck (19).
Take notice:
Please pay attention to the corresponding environmental
laws when disposing of used engine oil. We recommend you carry the
oil in a container to a central collecting point for used oils. Do not pour
used engine oil into the garbage nor into the sewer system, waste
pipes or even on the ground.